Technical parameters

Number of inputs and outputs: Number of digital outputs: 4
Factory setting: 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils
Probe length L [mm]: 472
Media: hydrous coolants; oils; oil-based media; water; media similar to water
Dielectric constant of the medium: > 2
Cannot be used for: extremely conductive media; adhering media; granulates; bulk material; acids; alkali
Tank pressure [bar]: 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)
Medium temperature [°C]: 0...35; (with climatic tube E43101 35...60 °C)
Medium temperature [°C]: 0...70
Medium temperature short time [°C]: 0...90; (< 1 h)
Medium temperature [°C]: 0...35; (with climatic tube E43101 35...60 °C)
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 50
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 3
Number of inputs and outputs: Number of digital outputs: 4
Total number of outputs: 4
Output signal: switching signal; IO-Link
Electrical design: PNP/NPN
Number of digital outputs: 4
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 200
Short-circuit protection: yes
Type of short-circuit protection: thermal, pulsed
Overload protection: yes
Factory setting: 2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils
Probe length L [mm]: 472
Active range A [mm]: 390
Inactive range I1 / I2 [mm]: 60 / 22
Set point SP [mm]: 35...390
Reset point rP [mm]: 30...385
In steps of [mm]: 5
Reference point OP [mm]: 139 - 163 - 188 - 212 - 236 - 261 - 285 - 310 - 334 - 358 - 383 - 407 - OFF
Hysteresis, OP [mm]: 3
Measuring range [°C]: 0...90
Set point SP [°C]: 0.5...90
Reset point rP [°C]: 0...89.5
In steps of [°C]: 0.5
Resolution of switching output [K]: 0.5
Measuring error [% of the final value]: ± 5
Repeatability: ± 2
Resolution [mm]: 5
Switch point accuracy [K]: ± 1,5
Resolution [K]: 0.5
Dynamic response T09 [s]: 90
Parameter setting options: hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; process value assignment
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 0x000013
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 4
Process data binary: 4
Min. process cycle time [ms]: 4.5
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -25...80
Protection: IP 67
EMC: DIN EN 61000-6-2 DIN EN 61000-6-4
Shock resistance: DIN EN 60068-2-27 15 g (11 ms)
DIN EN 60068-2-27: 15 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 195
Weight [g]: 443.5
Dimensions [mm]: Ø 16
Materials: stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PP; PA; TPV
Materials (wetted parts): PP
Display: Display unit 4 x LED, green (cm, inch, °C, °F) switching status 4 x LED, yellow (OUT4...OUT1) measured values alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit
Display unit: 4 x LED, green (cm, inch, °C, °F)
switching status: 4 x LED, yellow (OUT4...OUT1)
measured values: alphanumeric display, 4-digit
parameter setting: alphanumeric display, 4-digit
Notes: For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).; Please see the technical note under "Downloads"
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.44 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m