Ifm LR2759

Continuous level sensor (guided wave radar). LR0000B-EA01AKSKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

For the reliable level control in tanks and containers. Hygienic design for the requirements of the food and beverage industry. Clearly visible 4-digit LED display. Modular system consisting of evaluation unit and probe. Adaptation to different container heights through shortening of the probe

Technical parameters

Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Probe length L [mm]: 150...2000
Process connection: G 1 Aseptoflex Vario
Special feature: Gold-plated contacts
Media: Liquids
Dielectric constant of the medium: > 5
Recommended media: water; hydrous media
Medium temperature [°C]: -40...150; (For 3-A applications, the medium temperature is limited to 121 °C and COP cleaning is required.)
Tank pressure [bar]: -1...40
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 50
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 3
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link
Electrical design: PNP/NPN
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 150; (200 (...60 °C))
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable)
Max. load [Ω]: 500
Factory setting: Electrical design: NPN
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Probe length L [mm]: 150...2000
Active range A [mm]: L-40
Inactive range I1 / I2 [mm]: 30 / 10
Sampling rate [Hz]: 4
Set point SP [mm]: 15...L-30
Reset point rP [mm]: 10... L-35
In steps of [mm]: 1
Hysteresis [mm]: > 5
Measuring error [mm]: ± 7
Offset error [mm]: 5
Resolution [mm]: 1
Zero signal (current) [mA]: 4.0
Full signal (current) [mA]: 20
Temperature drift per 10 K: ± 0.2 %
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 0x000283
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -40...80
Storage temperature [°C]: -40...100
Protection: IP 68; IP 69K
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3 : in a metal tank DIN EN 61000-6-4 : in a plastic tank
DIN EN 61000-6-3: : in a metal tank
DIN EN 61000-6-4: : in a plastic tank
Shock resistance: DIN EN 60068-2-27 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m
DIN EN 60068-2-27: 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
DIN EN 60068-2-6: 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
MTTF [years]: 216
Weight [g]: 396.5
Materials: stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM
Materials (wetted parts): stainless steel (1.4404 / 316L); PEEK
Process connection: G 1 Aseptoflex Vario
Surface characteristics Ra/Rz of the wetted parts: < 0.8
Display: Display unit 3 x LED, green switching status 2 x LED, yellow level alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit
Display unit: 3 x LED, green
switching status: 2 x LED, yellow
level: alphanumeric display, 4-digit
parameter setting: alphanumeric display, 4-digit
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.40 kg
Length: 0.00 m
Width: 0.00 m