Ifm LR2350

Continuous level sensor (guided wave radar). LR0000BSEN34AKSKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

For the reliable level control in tanks and containers. Suitable for water, oils and coolants. Clearly visible 4-digit LED display. Modular system consisting of evaluation unit and probe. Adaptation to different container heights through shortening of the probe

Technical parameters

Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Probe length L [mm]: 150...2000
Process connection: 3/4" NPT
Special feature: Gold-plated contacts
Media: Liquids
Dielectric constant of the medium: > 5
Recommended media: water; hydrous media
Medium temperature [°C]: -20...100
Tank pressure [bar]: -1...16
MAWP (for applications according to CRN) [bar]: 16
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 50
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: < 3
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link
Electrical design: PNP/NPN
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 150; (200 (...60 °C))
Number of analogue outputs: 1
Analogue current output [mA]: 4...20, invertible; (scalable)
Max. load [Ω]: 500
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Probe length L [mm]: 150...2000
Active range A [mm]: L-40
Inactive range I1 / I2 [mm]: 30 / 10
Sampling rate [Hz]: 4
Set point SP [mm]: ≥ 15 ...L-30
Reset point rP [mm]: ≥ 10 ...L-35
In steps of [mm]: 1
Hysteresis [mm]: > 5
Measuring error [mm]: ± 7
Offset error [mm]: 5
Resolution [mm]: 1
Zero signal (current) [mA]: 4.0
Full signal (current) [mA]: 20
Temperature drift per 10 K: ± 0.2 %
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 0x0002DA
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -40...80
Storage temperature [°C]: -40...100
Protection: IP 68; IP 69K
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3 : in a metal tank DIN EN 61000-6-4 : in a plastic tank
DIN EN 61000-6-3: : in a metal tank
DIN EN 61000-6-4: : in a plastic tank
Shock resistance: DIN EN 60068-2-27 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m
DIN EN 60068-2-27: 50 g (11 ms) / 20 g (6 ms) with reference rod 0.5 m
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
DIN EN 60068-2-6: 20 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
MTTF [years]: 216
Weight [g]: 448
Materials: stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM
Materials (wetted parts): stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PTFE; FKM
Process connection: 3/4" NPT
Display: Display unit 3 x LED, green switching status 2 x LED, yellow level alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit
Display unit: 3 x LED, green
switching status: 2 x LED, yellow
level: alphanumeric display, 4-digit
parameter setting: alphanumeric display, 4-digit
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.45 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m