LMC110
Sensor for point level detection. LMFCE-B12E-QSKG-1/US
For the reliable level control in tanks and containers. Two programmable switching outputs, one of them with IO-Link communication interface. Preset to oil and oil-based media. Simple process connection via screw-in adapter. Reliable suppression of deposits or foam
| Number of inputs and outputs: | Number of digital outputs: 2 |
| Factory setting: | oils; oil-based media |
| Process connection: | G 1/2 external thread |
| Special feature: | Gold-plated contacts |
| Media: | water; hydrous media; oils; oil-based media; coolants; powder |
| Cannot be used for: | See the operating instructions, chapter "Function and features". |
| Medium temperature [°C]: | -25...100 |
| Probe length [mm]: | 28 |
| Tank pressure [bar]: | -1...40 |
| MAWP (for applications according to CRN) [bar]: | 40 |
| Medium temperature [°C]: | -25...100 |
| Operating voltage [V]: | 18...30 DC |
| Current consumption [mA]: | < 35 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Number of inputs and outputs: | Number of digital outputs: 2 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; IO-Link |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 50; (100 (...60 °C)) |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | thermal, pulsed |
| Overload protection: | yes |
| Factory setting: | oils; oil-based media |
| Response time [s]: | < 0.5 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 0x0002A3 |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 2.3 |
| Ambient temperature [°C]: | -25...85 |
| Storage temperature [°C]: | -40...85 |
| Protection: | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) |
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 : closed tanks DIN EN 61000-6-4 : open tanks |
| DIN EN 61000-6-3: | : closed tanks |
| DIN EN 61000-6-4: | : open tanks |
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 534 |
| UL approval: | UL Approval no. H003 |
| UL Approval no.: | H003 |
| Weight [g]: | 127.5 |
| Dimensions [mm]: | Ø 18.1 / L = 76.2 |
| Materials: | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection: | G 1/2 external thread |
| Display: | switching status LEDs, yellow operating status LEDs, green |
| switching status: | LEDs, yellow |
| operating status: | LEDs, green |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.13 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |