LMC100
Sensor for point level detection. LMFCE-B12E-QSKG-0/US
For the reliable level control in tanks and containers. Two programmable switching outputs, one of them with IO-Link communication interface. Preset to water and hydrous media. Simple process connection via screw-in adapter. Reliable suppression of deposits or foam
| Number of inputs and outputs: | Number of digital outputs: 2 | 
| Factory setting: | water; hydrous media | 
| Process connection: | G 1/2 external thread | 
| Special feature: | Gold-plated contacts | 
| Media: | water; hydrous media; oils; oil-based media; coolants; powder | 
| Cannot be used for: | See the operating instructions, chapter "Function and features". | 
| Medium temperature [°C]: | -25...100 | 
| Probe length [mm]: | 28 | 
| Tank pressure [bar]: | -1...40 | 
| MAWP (for applications according to CRN) [bar]: | 40 | 
| Medium temperature [°C]: | -25...100 | 
| Operating voltage [V]: | 18...30 DC | 
| Current consumption [mA]: | < 35 | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 2 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; IO-Link | 
| Electrical design: | PNP/NPN | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2.5 | 
| Permanent current rating of switching output DC [mA]: | 50; (100 (...60 °C)) | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | thermal, pulsed | 
| Overload protection: | yes | 
| Factory setting: | water; hydrous media | 
| Response time [s]: | < 0.5 | 
| Communication interface: | IO-Link | 
| Transmission type: | COM2 (38,4 kBaud) | 
| IO-Link revision: | 1.1 | 
| SDCI standard: | IEC 61131-9 | 
| IO-Link device ID: | 0x0002A2 | 
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
| SIO mode: | yes | 
| Required master port type: | A | 
| Process data analogue: | 1 | 
| Process data binary: | 2 | 
| Min. process cycle time [ms]: | 2.3 | 
| Ambient temperature [°C]: | -25...85 | 
| Storage temperature [°C]: | -40...85 | 
| Protection: | IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68) | 
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 : closed tanks DIN EN 61000-6-4 : open tanks | 
| DIN EN 61000-6-3: | : closed tanks | 
| DIN EN 61000-6-4: | : open tanks | 
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) | 
| DIN EN 60068-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) | 
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 534 | 
| UL approval: | UL Approval no. H003 | 
| UL Approval no.: | H003 | 
| Weight [g]: | 149 | 
| Dimensions [mm]: | Ø 18.1 / L = 76.2 | 
| Materials: | stainless steel (1.4404 / 316L); PEEK; PEI; FKM | 
| Materials (wetted parts): | stainless steel (1.4404 / 316L); PEEK; FKM | 
| Process connection: | G 1/2 external thread | 
| Display: | switching status LEDs, yellow operating status LEDs, green | 
| switching status: | LEDs, yellow | 
| operating status: | LEDs, green | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Country of Origin: | DE | 
| EAN: | |
| Weight: | 0.15 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |