Continuous level sensor with leakage monitoring. LL0264B-B-00KVPKG/US
Reliable level detection in containers and tanks. For use in water, oils and coolants. Easy adjustment to the medium to be measured. Clearly visible 4-digit LED display. Two programmable switching outputs for leakage detection
Number of inputs and outputs: | Number of digital outputs: 4 |
Probe length L [mm]: | 264 |
Special feature: | Gold-plated contacts |
Media: | hydrous coolants; oils; water; media similar to water |
Dielectric constant of the medium: | > 2 |
Cannot be used for: | extremely conductive media; adhering media; granulates; bulk material; acids; alkali |
Tank pressure [bar]: | 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) |
Medium temperature [°C]: | 0...35; (LL8022 + E43100: 0...65; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.) |
Medium temperature [°C]: | 0...70 |
Medium temperature short time [°C]: | 0...90 |
Medium temperature [°C]: | 0...35; (LL8022 + E43100: 0...65; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.) |
Operating voltage [V]: | 18...30 DC; (operating voltage "supply class 2" according to cULus) |
Current consumption [mA]: | < 60 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 3 |
Number of inputs and outputs: | Number of digital outputs: 4 |
Total number of outputs: | 4 |
Output signal: | switching signal |
Electrical design: | PNP |
Number of digital outputs: | 4 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 200 |
Short-circuit protection: | yes |
Type of short-circuit protection: | thermal, pulsed |
Overload protection: | yes |
Probe length L [mm]: | 264 |
Active range A [mm]: | 195 |
Inactive range I1 / I2 [mm]: | 53 / 15 |
Set point SP [mm]: | 25...190 |
Reset point rP [mm]: | 20...185 |
In steps of [mm]: | 5 |
Hysteresis [mm]: | 5 |
Overflow switch point OP [mm]: | 69 - 82 - 94 - 106 - 118 - 130 - 143 - 155 - 167 - 179 - 191 - 204 |
Hysteresis, OP [mm]: | 2 |
Display range [°C]: | -10...100 |
Measuring error [% of the final value]: | ± 5 |
Repeatability: | ± 2 |
Parameter setting options: | hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; settings for leakage monitoring |
Ambient temperature [°C]: | 0...60 |
Storage temperature [°C]: | -25...80 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN EN 60068-2-29 15 g (11 ms) |
DIN EN 60068-2-29: | 15 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 202 |
Weight [g]: | 344.6 |
Dimensions [mm]: | Ø 16 |
Materials: | stainless steel (1.4301 / 304); FKM; NBR; PBT; PC; PEI; PP; TPE-V |
Materials (wetted parts): | PP |
Display: | display unit / status 4 x LED, green switching status 4 x LED, yellow level alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit |
display unit / status: | 4 x LED, green |
switching status: | 4 x LED, yellow |
level: | alphanumeric display, 4-digit |
parameter setting: | alphanumeric display, 4-digit |
Notes: | discontinued article; For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.34 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |