Ifm LL8022

Continuous level sensor with leakage monitoring. LL0264B-B-00KVPKG/US

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

Reliable level detection in containers and tanks. For use in water, oils and coolants. Easy adjustment to the medium to be measured. Clearly visible 4-digit LED display. Two programmable switching outputs for leakage detection

Technical parameters

Number of inputs and outputs: Number of digital outputs: 4
Probe length L [mm]: 264
Special feature: Gold-plated contacts
Media: hydrous coolants; oils; water; media similar to water
Dielectric constant of the medium: > 2
Cannot be used for: extremely conductive media; adhering media; granulates; bulk material; acids; alkali
Tank pressure [bar]: 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)
Medium temperature [°C]: 0...35; (LL8022 + E43100: 0...65; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.)
Medium temperature [°C]: 0...70
Medium temperature short time [°C]: 0...90
Medium temperature [°C]: 0...35; (LL8022 + E43100: 0...65; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.)
Operating voltage [V]: 18...30 DC; (operating voltage "supply class 2" according to cULus)
Current consumption [mA]: < 60
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 3
Number of inputs and outputs: Number of digital outputs: 4
Total number of outputs: 4
Output signal: switching signal
Electrical design: PNP
Number of digital outputs: 4
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 200
Short-circuit protection: yes
Type of short-circuit protection: thermal, pulsed
Overload protection: yes
Probe length L [mm]: 264
Active range A [mm]: 195
Inactive range I1 / I2 [mm]: 53 / 15
Set point SP [mm]: 25...190
Reset point rP [mm]: 20...185
In steps of [mm]: 5
Hysteresis [mm]: 5
Overflow switch point OP [mm]: 69 - 82 - 94 - 106 - 118 - 130 - 143 - 155 - 167 - 179 - 191 - 204
Hysteresis, OP [mm]: 2
Display range [°C]: -10...100
Measuring error [% of the final value]: ± 5
Repeatability: ± 2
Parameter setting options: hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; settings for leakage monitoring
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -25...80
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN EN 60068-2-29 15 g (11 ms)
DIN EN 60068-2-29: 15 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 202
Weight [g]: 344.6
Dimensions [mm]: Ø 16
Materials: stainless steel (1.4301 / 304); FKM; NBR; PBT; PC; PEI; PP; TPE-V
Materials (wetted parts): PP
Display: display unit / status 4 x LED, green switching status 4 x LED, yellow level alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit
display unit / status: 4 x LED, green
switching status: 4 x LED, yellow
level: alphanumeric display, 4-digit
parameter setting: alphanumeric display, 4-digit
Notes: discontinued article; For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.34 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m