LK1224
Electronic level sensor. LK0728B-B-00KUPKG/US/WHG
Number of inputs and outputs: | Number of digital outputs: 2 |
Factory setting: | hydrous coolants; water; media similar to water |
Probe length L [mm]: | 728 |
Special feature: | Gold-plated contacts |
Media: | hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric constant of the medium: | > 2 |
Cannot be used for: | extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applications |
Maximum speed of the change of level [mm/s]: | 300 |
Tank pressure [bar]: | 0.5; (unpressurized for applications to WHG (German Federal Water Act)) |
Medium temperature [°C]: | 0...35; (with climatic tube E43102: 35...55 °C; not for applications to WHG (German Federal Water Act)) |
Medium temperature [°C]: | 0...70 |
Medium temperature short time [°C]: | 0...90; (< 1 h) |
Medium temperature [°C]: | 0...35; (with climatic tube E43102: 35...55 °C; not for applications to WHG (German Federal Water Act)) |
Operating voltage [V]: | 12...30 DC |
Current consumption [mA]: | < 50 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | < 3 |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 200 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Factory setting: | hydrous coolants; water; media similar to water |
Probe length L [mm]: | 728 |
Active range A [mm]: | 585 |
Inactive range I1 / I2 [mm]: | 104 / 39 |
Set point SP [mm]: | 60...590 |
Reset point rP [mm]: | 50...580 |
In steps of [mm]: | 10 |
Reference point OP [mm]: | 200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 - 610 - OFF |
Hysteresis, OP [mm]: | 4 |
Measuring error [% of the final value]: | ± 5 |
Repeatability: | ± 2 |
Resolution [mm]: | 5 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 804 d / 00 03 24 h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 3 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 3.2 |
Ambient temperature [°C]: | 0...60 |
Storage temperature [°C]: | -25...80 |
Protection: | IP 67 |
Approval: | WHG; General building authority approval; overflow prevention |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-4 |
Shock resistance: | DIN EN 60068-2-27 15 g (11 ms) |
DIN EN 60068-2-27: | 15 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 266 |
Weight [g]: | 706.4 |
Dimensions [mm]: | Ø 16 |
Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV |
Materials (wetted parts): | PP |
Display: | Display unit 2 x LED, green (cm, inch) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit |
Display unit: | 2 x LED, green (cm, inch) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
parameter setting: | alphanumeric display, 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.71 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |