LDP100
Optical oil particle monitor. OIL PARTICLE MONITOR
Trend monitoring by analysis of the particle concentration. Indication of purity class on the LCD display. Applications up to 420 bar. Intuitive, user-friendly handling. CAN bus, analogue and switching outputs
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Media: | mineral oils (e.g. HLP); ester oils (e.g. HEES); biodegradable oils (e.g. HETG) |
Medium temperature [°C]: | -10...80 |
Operating voltage [V]: | 9...33 DC |
Current consumption [mA]: | 9...50 |
Protection class: | III |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Number of digital outputs: | 1 |
Permanent current rating of switching output DC [mA]: | 500 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | (Ub - 4 V) / 20 mA; Ub = 24 V: 1000 |
Short-circuit proof: | no |
Overload protection: | no |
Measuring range: | 10...22; (range number) |
Display range: | 0...24; (range number) |
Accuracy: | ± 1; (range number) |
Parameter setting options: | via buttons, PC or digital I/O |
Communication interface: | CAN |
Ambient temperature [°C]: | -10...60 |
Storage temperature [°C]: | -20...60 |
Protection: | IP 67 |
MTTF [years]: | 129 |
Pressure Equipment Directive: | article 3, paragraph (3) - Sound Engineering Practice |
Weight [g]: | 829 |
Materials (wetted parts): | stainless steel (1.4028 / 420); sapphire; NBR; chromium |
Display: | LC display, displayed value conforms to the cleanliness level to ISO 4406:99 and SAE AS4059E |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.83 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |