LDL100
Conductive conductivity sensor. COND CONDUCTIVITY HYG G1/2
Reduce inaccuracies associated with a time-based cleaning process. Improve process performance with flexible measurement points. Compact, high-quality sensor design prevents failures and unplanned downtime. Simplify your installation and commissioning processes. Loss-free signal transmission of measurement values
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Process connection: | G 1/2 external thread |
| Special feature: | Gold-plated contacts |
| Media: | conductive liquids |
| Note on media: | water milk CIP liquids |
| Cannot be used for: | See the operating instructions, chapter "Function and features". |
| Medium temperature [°C]: | -25...100; (< 1 h: 150) |
| Pressure rating [bar]: | 16 |
| Vacuum resistance [mbar]: | -1000 |
| Operating voltage [V]: | 18...30 DC |
| Current consumption [mA]: | < 60 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 2 |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal; IO-Link |
| Output function: | analogue output; scalable; selectable conductivity / temperature |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 500 |
| Measuring range [µS/cm]: | 100...15000 |
| Measuring range [°C]: | -25...150 |
| Accuracy (in the measuring range): | 10 % MW ± 25 µS/cm |
| Resolution [µS/cm]: | 1 |
| Drift [%/K]: | 0,2 %/K MW ± 25 µS/cm |
| Repeatability: | 5 % MW ± 25 µS/cm |
| Long-term stability: | 1 % MW ± 25 µS/cm |
| Accuracy [K]: | 20...50 °C: < ± 0,5 K; -25...150 °C: < ± 1,5 K |
| Repeatability [K]: | 0,2 |
| Resolution [K]: | 0.1 |
| Response time [s]: | < 2; (T09; Damping = 0) |
| Response time [s]: | < 9; (T09) |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 0x000399 / 921 |
| Profiles: | Measuring Sensor, Identification and Diagnosis |
| SIO mode: | no |
| Required master port type: | A |
| Process data analogue: | 1 |
| Min. process cycle time [ms]: | 5.6 |
| Ambient temperature [°C]: | -40...60 |
| Storage temperature [°C]: | -40...85 |
| Protection: | IP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP 68) |
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 172 |
| Weight [g]: | 270.5 |
| Materials: | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
| Materials (wetted parts): | PEEK; stainless steel (1.4404 / 316L) |
| Process connection: | G 1/2 external thread |
| Remarks: | MW = measured value |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 (EN 61067-2-101); Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.27 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |