LDH100
Oil humidity sensor. OIL HUMIDITY SENSOR
Continuous condition monitoring of oils and air. Two analogue outputs for relative moisture and temperature. High pressure rating. Quick installation via process connection
Number of inputs and outputs: | Number of analogue outputs: 2 |
Process connection: | G 3/4 |
Media: | mineral oils; synthetic esters; biodegradable oils; air |
Tank pressure [bar]: | 50 |
Medium temperature [°C]: | -40...105 |
Operating voltage [V]: | 9...33 DC |
Current consumption [mA]: | < 25 |
Protection class: | III |
Reverse polarity protection: | no |
Number of inputs and outputs: | Number of analogue outputs: 2 |
Total number of outputs: | 2 |
Number of analogue outputs: | 2 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 8; ((Ub - 8) x 25) |
Resolution of analogue output: | φ: 1% / T: 0.1 K |
Measuring range [°C]: | -20...120 |
Accuracy: | φ: ± 3 % / T: ± 2 % |
Response time [s]: | 1.3 |
Ambient temperature [°C]: | -40...85 |
Storage temperature [°C]: | -40...85 |
Max. relative air humidity [%]: | 100 |
Protection: | IP 67 |
EMC: | EN 13309 IEC 61000-6-2 : 2005 IEC 61000-6-4 : 2006 + AMD1: 2010 |
IEC 61000-6-2: | : 2005 |
IEC 61000-6-4: | : 2006 + AMD1: 2010 |
Vibration resistance: | test following DIN EN 60068-2-6 |
MTTF [years]: | 90 |
Weight [g]: | 176.6 |
Materials (wetted parts): | aluminium; HNBR; polyurethane resin; epoxy resin |
Process connection: | G 3/4 |
Remarks: | accuracy values expressed in percent refer to the measuring span |
Notes: | For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet). |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.18 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |