KI000A
Capacitive sensor. KIE2150NFBOA/3D
For applications in hazardous areas. With combined AC/DC output stage. Easy setting of the sensing range via potentiometer. Two-wire technology. Output function normally open / normally closed programmable
Output function: | normally open / normally closed; (selectable) |
Sensing range [mm]: | 15 |
Housing: | threaded type |
Dimensions [mm]: | M30 x 1.5 / L = 150 |
Operating voltage [V]: | 30...250 AC / 20...250 DC |
Protection class: | II |
Reverse polarity protection: | yes |
Output function: | normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V]: | 8 |
Max. voltage drop switching output AC [V]: | 10 |
Minimum load current [mA]: | 5 |
Max. leakage current [mA]: | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA]: | 100; (150 (...40 °C)) |
Permanent current rating of switching output DC [mA]: | 100; (150 (...40 °C)) |
Short-time current rating of switching output [mA]: | 1000; (20ms / 0,5Hz) |
Switching frequency AC [Hz]: | 10 |
Switching frequency DC [Hz]: | 10 |
Notes on switching frequency: | only for resistive loads; 2 Hz for utilisation category AC-140 |
Short-circuit proof: | no |
Overload protection: | no |
Sensing range [mm]: | 15 |
Sensing range adjustable: | yes |
Factory setting sensing range [mm]: | 15 |
Real sensing range Sr [mm]: | 15 ± 10 % |
Correction factor: | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr]: | 1...15 |
Switch point drift [% of Sr]: | -20...20 |
Ambient temperature [°C]: | -20...60 |
Protection: | IP 65; IP 67 |
ATEX marking: | II 3D Ex tc IIIC T90°C Dc X |
EMC: | EN 61000-4-2 ESD kV / 8 kV AD EN 61000-4-3 HF radiated 3 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 1 kV line to line, Ri: 2 Ohm EN 61000-4-6 HF conducted 3 V EN 55011 class B |
EN 61000-4-2 ESD: | kV / 8 kV AD |
EN 61000-4-3 HF radiated: | 3 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 1 kV line to line, Ri: 2 Ohm |
EN 61000-4-6 HF conducted: | 3 V |
EN 55011: | class B |
MTTF [years]: | 305 |
Weight [g]: | 151 |
Housing: | threaded type |
Mounting: | non-flush mountable |
Dimensions [mm]: | M30 x 1.5 / L = 150 |
Thread designation: | M30 x 1.5 |
Materials: | PBT; PA |
Display: | switching status 1 x LED, yellow |
switching status: | 1 x LED, yellow |
Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Accessories (supplied): | lock nuts: 2 |
Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. |
Pack quantity: | 1 pcs. |
Connection: | terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.15 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |