Ifm KD001A

Capacitive sensor. KDE2060-FBOA/NI/3D

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

With combined AC/DC output and two-wire technology. Long sensing range of 60 mm. Easy setting of the sensing range via potentiometer. For applications in hazardous areas. Robust housing for use in harsh industrial environments

Technical parameters

Output function: normally open / normally closed; (selectable)
Sensing range [mm]: 60
Housing: rectangular
Dimensions [mm]: 105 x 80 x 42
Operating voltage [V]: 20...250 AC/DC
Protection class: II
Reverse polarity protection: no
Output function: normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V]: 8
Max. voltage drop switching output AC [V]: 10
Minimum load current [mA]: 5
Max. leakage current [mA]: 2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC)
Permanent current rating of switching output AC [mA]: 130; (250 (...40 °C))
Permanent current rating of switching output DC [mA]: 130; (250 (...40 °C))
Short-time current rating of switching output [mA]: 1500; (20 ms / 0,5 Hz)
Switching frequency AC [Hz]: 4
Switching frequency DC [Hz]: 4
Notes on switching frequency: only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proof: no
Overload protection: no
Sensing range [mm]: 60
Sensing range adjustable: yes
Factory setting sensing range [mm]: 60
Real sensing range Sr [mm]: 60 ± 10 %
Correction factor: glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2
Hysteresis [% of Sr]: 1...15
Switch point drift [% of Sr]: -15...15
Ambient temperature [°C]: -20...60
Protection: IP 65
Increased immunity: yes
ATEX marking: II 3D Ex tc IIIC T90°C Dc X IP65
EMC: EN 60947-5-2
MTTF [years]: 270
Weight [g]: 281.5
Housing: rectangular
Mounting: non-flush mountable
Dimensions [mm]: 105 x 80 x 42
Materials: PPE modified; PA
Tightening torque [Nm]: housing screws: 0,9 Nm; screws: 4 Nm
Display: switching status 1 x LED, yellow
switching status: 1 x LED, yellow
Required protection: miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.
Remarks: Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity: 1 pcs.
Connection: terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.28 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m