JN2201
Inclination sensor. INC-M2M090ABIAKG/US
Precise measurement of angles of inclination on X and Y axes. High measurement accuracy across the total angular range in two axes. With two programmable switching outputs, two scalable analogue outputs and IO-Link. Compact and robust housing. High protection rating for the requirements of harsh industrial environments
| Dimensions [mm]: | 90 x 62 x 33.2 |
| Number of measurement axes: | 2 |
| Application: | High-precision inclination measurement in 2 axes for mobile and industrial applications |
| Operating voltage [V]: | 9.2...30 DC; (voltage output: 12...30 DC; IO-Link: 18...30 DC) |
| Current consumption [mA]: | 100; (24 V DC, 25 °C) |
| Max. current consumption [mA]: | 380; (9,2 V DC; -40 °C) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Reverse polarity protection: | yes |
| Max. initialisation time [ms]: | 1000 |
| Power-on delay time [s]: | 300; (warm-up time) |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 2 |
| Total number of outputs: | 4 |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (programmable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C)) |
| Number of analogue outputs: | 2 |
| Analogue current output [mA]: | 4...20; (in case of a fault: 2 mA) |
| Max. load [Ω]: | 220; (220 (9,2…15 V) / 500 (15…30 V)) |
| Analogue voltage output [V]: | 2...10; (in case of a fault: 1 V) |
| Min. load resistance [Ω]: | 1000; (10000 (12...13,5 V) / 1000 (13,5...30 V)) |
| Precision analogue output [%]: | ≤ 1 |
| Short-circuit protection: | yes |
| Overload protection: | yes |
| Measuring principle: | MEMS capacitive |
| Number of measurement axes: | 2 |
| Angular range [°]: | ± 45 |
| Limit frequency [Hz]: | 0.5...10; (parameterisable) |
| Accuracy [°]: | ≤ ± 0,01 |
| Repeatability [°]: | ≤ ± 0,01 |
| Resolution [°]: | 0.01 |
| Temperature coefficient [1/K]: | ≤ ± 0,0008 |
| Parameter setting options: | angle (X/Y); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 CDV |
| IO-Link device ID: | 416 / 0x0001A0 |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 2 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 5 |
| Ambient temperature [°C]: | -40...85 |
| Storage temperature [°C]: | -40...85 |
| Protection: | IP 65; IP 67; IP 68; IP 69K |
| EMC: | DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD DIN EN 61000-4-3 HF radiated 10 V/m DIN EN 61000-4-4 Burst 2 kV DIN EN 61000-4-6 HF conducted 10 V DIN EN 55022 class B / CISPR 16-2-3 30 - 1000 MHz CISPR 25 ECE R 10 30 - 1000 MHz narrowband and broadband ISO 11452-2 ECE R 10 20 - 2000 MHz / 30 V/m ISO 7637-2 ECE R 10 pulse 1, 2a, 2b, 3a, 3b, 4, and pulse emission during operation, switching-on, switching-off ISO 7637-3 - 80 V pulse a / + 80 V pulse b |
| DIN EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| DIN EN 61000-4-3 HF radiated: | 10 V/m |
| DIN EN 61000-4-4 Burst: | 2 kV |
| DIN EN 61000-4-6 HF conducted: | 10 V |
| DIN EN 55022 class B / CISPR 16-2-3: | 30 - 1000 MHz |
| CISPR 25 ECE R 10: | 30 - 1000 MHz narrowband and broadband |
| ISO 11452-2 ECE R 10: | 20 - 2000 MHz / 30 V/m |
| ISO 7637-2 ECE R 10: | pulse 1, 2a, 2b, 3a, 3b, 4, and pulse emission during operation, switching-on, switching-off |
| ISO 7637-3: | - 80 V pulse a / + 80 V pulse b |
| Shock resistance: | DIN EN 60068-2-27 100 g 1 ms / 10000 impacts per axis (X/Y) DIN EN 60068-2-29 30 g 6 ms / 24000 shock (bump) |
| DIN EN 60068-2-27: | 100 g 1 ms / 10000 impacts per axis (X/Y) |
| DIN EN 60068-2-29: | 30 g 6 ms / 24000 shock (bump) |
| Vibration resistance: | DIN EN 60068-2-64 10...2000 Hz Test VII / random, mounting place car body DIN EN 60068-2-6 10...500 Hz / 10 g 10 cycles/axis, sine |
| DIN EN 60068-2-64: | 10...2000 Hz Test VII / random, mounting place car body |
| DIN EN 60068-2-6: | 10...500 Hz / 10 g 10 cycles/axis, sine |
| Salt spray test: | DIN EN 60068-2-52 severity level 5 (motor vehicle) |
| DIN EN 60068-2-52: | severity level 5 (motor vehicle) |
| Damp heat: | DIN EN 60068-2-30 55 °C cyclic upper temperature / 95 % rh 2 cycles of 24 h |
| DIN EN 60068-2-30: | 55 °C cyclic upper temperature / 95 % rh 2 cycles of 24 h |
| MTTF [years]: | 176 |
| Standard: | Compliant with ECE R 10, rev. 5; ISO 7637-3: 2007-07 |
| Weight [K40]: | 451 |
| Dimensions [mm]: | 90 x 62 x 33.2 |
| Materials: | housing: diecast zinc nickel-plated |
| Display: | operation 1 x LED, green switch point 1 x LED, yellow |
| operation: | 1 x LED, green |
| switch point: | 1 x LED, yellow |
| Accessories (supplied): | Protective cover |
| Pack quantity: | 1 pcs. |
| switch point: | SP1 |
| reset point: | rP1 |
| switch point: | SP2 |
| reset point: | rP2 |
| Analogue start point: | ASP1 |
| Analogue end point: | AEP1 |
| Analogue start point: | ASP2 |
| Analogue end point: | AEP2 |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.45 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |