IV5060
Inductive sensor. IVE3020UBPKG/US
Five positions of the sensing face selectable. Long sensing range for high uptime. Robust housing for use in harsh industrial environments. For use in materials handling. LED display to check switching status and operation
Electrical design: | PNP |
Output function: | normally open |
Sensing range [mm]: | 20 |
Housing: | rectangular |
Dimensions [mm]: | 40 x 40 x 118 |
Special feature: | Magnetic-field immune |
Magnetic-field immune: | yes |
Operating voltage [V]: | 10...30 DC; ("supply class 2" according to UL; "supply limited voltage / current" to UL) |
Current consumption [mA]: | 20; (24 V) |
Protection class: | II |
Reverse polarity protection: | yes |
Electrical design: | PNP |
Output function: | normally open |
Max. voltage drop switching output DC [V]: | 3 |
Permanent current rating of switching output DC [mA]: | 200 |
Switching frequency DC [Hz]: | 5 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Sensing range [mm]: | 20 |
Real sensing range Sr [mm]: | 20 ± 10 % |
Operating distance [mm]: | 0...16.2 |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.3 |
Hysteresis [% of Sr]: | 1...10 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -25...85 |
Note on ambient temperature: | for UL application: ...70 °C |
Max. height above sea level [m]: | 2000 |
Protection: | IP 68; IP 69K |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
EN 55011: | class B |
Vibration resistance: | EN 60682-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
EN 60682-2-6 Fc: | 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
Shock resistance: | EN 60682-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
EN 60682-2-27 Ea: | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
Continuous shock resistance: | EN 60682-2-29 Eb 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
EN 60682-2-29 Eb: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
MTTF [years]: | 582.6 |
UL approval: | Ta 0...70 °C Enclosure type Type 1 voltage supply Class 2 File number UL E174191 |
Ta: | 0...70 °C |
Enclosure type: | Type 1 |
voltage supply: | Class 2 |
File number UL: | E174191 |
Weight [K40]: | 253 |
Housing: | rectangular |
Mounting: | flush mountable |
Dimensions [mm]: | 40 x 40 x 118 |
Materials: | PA 6.6; diecast zinc epoxy coated; sensing face: PA 6.6; LED window: PA; lower part: PA 6.6; screws: stainless steel |
Display: | switching status 1 x LED, yellow operation 1 x LED, green |
switching status: | 1 x LED, yellow |
operation: | 1 x LED, green |
Remarks: | 5 positions of the active zone possible For use in NFPA 79 applications only |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | ID |
EAN: | |
Weight: | 0.25 kg |
Length: | 0.00 m |
Width: | 0.00 m |