IV0009
Inductive sensor. IVE2020-FBKA
Five positions of the sensing face selectable. Long sensing range for high uptime. Robust housing for use in harsh industrial environments. For use in materials handling. Output function normally open / normally closed programmable
Output function: | normally open / normally closed; (selectable) |
Sensing range [mm]: | 20 |
Housing: | rectangular |
Dimensions [mm]: | 40 x 40 x 118 |
Operating voltage [V]: | 24...250 AC / 24...230 DC |
Protection class: | II |
Reverse polarity protection: | yes |
Output function: | normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V]: | 5 |
Max. voltage drop switching output AC [V]: | 8 |
Minimum load current [mA]: | 5 |
Max. leakage current [mA]: | 1.5 |
Permanent current rating of switching output AC [mA]: | 500 |
Permanent current rating of switching output DC [mA]: | 500 |
Switching frequency AC [Hz]: | 30 |
Switching frequency DC [Hz]: | 100 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Sensing range [mm]: | 20 |
Real sensing range Sr [mm]: | 20 ± 10 % |
Operating distance [mm]: | 0...16.2 |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr]: | 1...10 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -25...85 |
Note on ambient temperature: | for UL application: ...70 °C |
Max. height above sea level [m]: | 2000 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 8 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 15 V EN 55011 Class A |
EN 61000-4-2 ESD: | 8 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 15 V |
EN 55011: | Class A |
Vibration resistance: | EN 60068-2-6 Fc 10 g (10...2000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
EN 60068-2-6 Fc: | 10 g (10...2000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
Shock resistance: | EN 60068-2-27 Ea 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
EN 60068-2-27 Ea: | 30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
Continuous shock resistance: | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
EN 60068-2-27: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
MTTF [years]: | 272.6 |
UL approval: | Ta 0...70 °C Enclosure type Type 1 File number UL E174191 |
Ta: | 0...70 °C |
Enclosure type: | Type 1 |
File number UL: | E174191 |
Weight [K40]: | 268 |
Housing: | rectangular |
Mounting: | flush mountable |
Dimensions [mm]: | 40 x 40 x 118 |
Materials: | PA 6.6; diecast zinc epoxy coated; sensing face: PA 6.6; LED window: PA; screws: stainless steel stainless steel (1.4305 / 303) |
Display: | switching status 1 x LED, yellow operation 1 x LED, green |
switching status: | 1 x LED, yellow |
operation: | 1 x LED, green |
Remarks: | 5 positions of the active zone possible Cable gland (E11270) to be ordered separately For use in NFPA 79 applications only |
Pack quantity: | 1 pcs. |
Connection: | terminals: ...2.5 mm²; Cable gland: M20 X 1.5 |
ECCN: | |
Country of Origin: | CZ |
EAN: | |
Weight: | 0.27 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |