Technical parameters

Electrical design: PNP/NPN; (parameterisable)
Output function: normally open / normally closed; (parameterisable)
Communication interface: IO-Link
Housing: rectangular
Dimensions [mm]: 40 x 40 x 54
Operating voltage [V]: 15...30 DC
Current consumption [mA]: < 33
Protection class: II
Reverse polarity protection: yes
Electrical design: PNP/NPN; (parameterisable)
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: 100
Analogue voltage output [V]: 0...10; (linear; gradient: 0,3125 V/mm; for frontal approach and for target made of mild steel: 105 x 105 x 1 mm)
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Overload protection: yes
Measuring range [mm]: 3...35
Switch point IO-Link [mm]: 6.13...32.69
Correction factor: steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.5 / copper: 0.4
Hysteresis [% of Sr]: 3...15
Note on hysteresis: parameterisable
Linearity error of analogue output [%]: ± 2; (of the final value of the measuring range)
Repeatability analogue output [%]: ± 2; (of the final value of the measuring range)
Temperature coefficient [%/K vom MEW]: ±0,15
Temperature drift [% vom MEW]: ±5
Response time [ms]: < 20
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 1206d / 0004B6h
Profiles: Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel
SIO mode: yes
Required master port type: A
Min. process cycle time [ms]: 3.2
IO-Link process data (cyclical): function bit length process value 16 device status 4 binary switching information 2
function: bit length
process value: 16
device status: 4
binary switching information: 2
IO-Link functions (acyclical): switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag
Note: For further information please see the IODD PDF file under "Downloads"
Ambient temperature [°C]: -25...80
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
EN 55011: class B
MTTF [years]: 231
UL approval: Ta -25...70 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. A026 File number UL E174191
Ta: -25...70 °C
Enclosure type: Type 1
voltage supply: Limited Voltage/Current
UL Approval no.: A026
File number UL: E174191
Weight [g]: 158.5
Housing: rectangular
Mounting: non-flush mountable
Dimensions [mm]: 40 x 40 x 54
Materials: PA; stainless steel (1.4404 / 316L)
Display: target in measuring range 1 x LED, yellow lights target outside measuring range 1 x LED, yellow flashing operation LED, green
target in measuring range: 1 x LED, yellow lights
target outside measuring range: 1 x LED, yellow flashing
operation: LED, green
Remarks: Installation only with stainless steel plate 16x40x3 and 2 cylinder screws ISO 4762-12.9
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.16 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m