IM5139
Inductive analogue sensor with IO-Link. IMC3015A1PKG/US
Non-contact measurement of distances up to 15 mm. Precise linearised current output. Wide operating temperature range. High repeatability. LED display to check working range and operation
| Electrical design: | PNP/NPN; (parameterisable) |
| Output function: | normally open / normally closed; (parameterisable) |
| Communication interface: | IO-Link |
| Housing: | rectangular |
| Dimensions [mm]: | 40 x 40 x 54 |
| Operating voltage [V]: | 15...30 DC |
| Current consumption [mA]: | < 33 |
| Protection class: | II |
| Reverse polarity protection: | yes |
| Electrical design: | PNP/NPN; (parameterisable) |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 100 |
| Switching frequency DC [Hz]: | 100 |
| Analogue current output [mA]: | 4...20; (linear; gradient: 1,143 mA/mm; for frontal approach and for target made of mild steel: 45 x 45 x 1 mm) |
| Max. load [Ω]: | 500; (Ub <=18 V; ; Max. load <=400 Ω) |
| Short-circuit protection: | yes |
| Overload protection: | yes |
| Measuring range [mm]: | 1...15 |
| Switch point IO-Link [mm]: | 2.37...13.99 |
| Correction factor: | steel: 1 / stainless steel: 0.9 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr]: | 3...15 |
| Note on hysteresis: | parameterisable |
| Linearity error of analogue output [%]: | ± 2; (of the final value of the measuring range) |
| Repeatability analogue output [%]: | ± 2; (of the final value of the measuring range) |
| Temperature coefficient [%/K vom MEW]: | ±0,15 |
| Temperature drift [% vom MEW]: | ±5 |
| Response time [ms]: | < 20 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 1205d / 0004B5h |
| Profiles: | Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel |
| SIO mode: | yes |
| Required master port type: | A |
| Min. process cycle time [ms]: | 3.2 |
| IO-Link process data (cyclical): | function bit length process value 16 device status 4 binary switching information 2 |
| function: | bit length |
| process value: | 16 |
| device status: | 4 |
| binary switching information: | 2 |
| IO-Link functions (acyclical): | switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag |
| Note: | For further information please see the IODD PDF file under "Downloads" |
| Ambient temperature [°C]: | -25...80 |
| Protection: | IP 67 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| EN 55011: | class B |
| MTTF [years]: | 231 |
| UL approval: | Ta -25...70 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. A025 File number UL E174191 |
| Ta: | -25...70 °C |
| Enclosure type: | Type 1 |
| voltage supply: | Limited Voltage/Current |
| UL Approval no.: | A025 |
| File number UL: | E174191 |
| Weight [K40]: | 152 |
| Housing: | rectangular |
| Sensing face: | 5 positions selectable |
| Mounting: | flush mountable |
| Dimensions [mm]: | 40 x 40 x 54 |
| Materials: | PA; brass white bronze coated |
| Display: | target in measuring range 1 x LED, yellow lights target outside measuring range 1 x LED, yellow flashing operation LED, green |
| target in measuring range: | 1 x LED, yellow lights |
| target outside measuring range: | 1 x LED, yellow flashing |
| operation: | LED, green |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.15 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |