IM001A
Inductive sensor. IME2020BFBOA/3D
For applications in hazardous areas. With combined AC/DC output and two-wire technology. Output function normally open / normally closed programmable. Robust housing for use in harsh industrial environments. Five positions of the sensing face selectable
| Output function: | normally open / normally closed; (selectable) | 
| Sensing range [mm]: | 20 | 
| Housing: | rectangular | 
| Dimensions [mm]: | 40 x 40 x 105 | 
| Operating voltage [V]: | 20...250 AC/DC | 
| Protection class: | II | 
| Reverse polarity protection: | no | 
| Output function: | normally open / normally closed; (selectable) | 
| Max. voltage drop switching output DC [V]: | 6 | 
| Max. voltage drop switching output AC [V]: | 6.5 | 
| Minimum load current [mA]: | 5 | 
| Max. leakage current [mA]: | 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) | 
| Permanent current rating of switching output AC [mA]: | 150 | 
| Permanent current rating of switching output DC [mA]: | 100 | 
| Short-time current rating of switching output [mA]: | 2200; (20 ms / 0,5 Hz) | 
| Switching frequency AC [Hz]: | 10 | 
| Switching frequency DC [Hz]: | 10 | 
| Notes on switching frequency: | only for resistive loads; 2 Hz for utilisation category AC-140 | 
| Short-circuit proof: | no | 
| Overload protection: | no | 
| Sensing range [mm]: | 20 | 
| Real sensing range Sr [mm]: | 20 ± 10 % | 
| Operating distance [mm]: | 0...16.2 | 
| Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 | 
| Hysteresis [% of Sr]: | 1...20 | 
| Switch point drift [% of Sr]: | -10...10 | 
| Ambient temperature [°C]: | -20...60 | 
| Protection: | IP 65; IP 67 | 
| ATEX marking: | II 3D Ex tc IIIC T95°C Dc X | 
| EMC: | EN 60947-5-2 | 
| MTTF [years]: | 567 | 
| Weight [g]: | 245.5 | 
| Housing: | rectangular | 
| Mounting: | flush mountable | 
| Dimensions [mm]: | 40 x 40 x 105 | 
| Materials: | PC; PA; stainless steel | 
| Display: | switching status 1 x LED, yellow | 
| switching status: | 1 x LED, yellow | 
| Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. | 
| Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. 5 positions of the active zone possible | 
| Pack quantity: | 1 pcs. | 
| Connection: | terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm | 
| ECCN: | |
| Country of Origin: | DE | 
| EAN: | |
| Weight: | 0.25 kg | 
| Length: | 0.00 m | 
| Width: | 0.00 m | 
| Height: | 0.00 m |