Ifm II504A

Inductive full-metal sensor. IIK3010-BPKG/AM/US104DPS/2D/3G

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

For applications in hazardous areas. High protection rating for the requirements of harsh industrial environments. Metal sensing face for heavy duty. Special mechanical stability ensures high plant safety. Clearly visible indication of the switching status

Technical parameters

Electrical design: PNP
Output function: normally open
Sensing range [mm]: 10
Housing: threaded type
Dimensions [mm]: M30 x 1.5 / L = 70
Special feature: Gold-plated contacts; Full-metal housing
Pressure rating [bar]: 100
Note on pressure rating: sensing face
Operating voltage [V]: 10...36 DC
Current consumption [mA]: < 20
Protection class: III
Reverse polarity protection: yes
Electrical design: PNP
Output function: normally open
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 40
Switching frequency DC [Hz]: 50
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Sensing range [mm]: 10
Operating distance [mm]: 0...8.1
Correction factor: steel: 1 / stainless steel: 0.7 / brass: 0.8 / aluminium: 0.6 / copper: 0.3
Hysteresis [% of Sr]: 1...20
Ambient temperature [°C]: -40...60
Protection: IP 67; (when used outside the hazardous area: IP 65, IP 66, IP 67, IP 68, IP 69K)
Approval: BVS 12 ATEX E 045 X; IECEx BVS 12.0030 X
ATEX marking: II 3G Ex nA IIC T6 Gc
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 emission class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
EN 55011 emission: class B
Impact resistance: 1 J
MTTF [years]: 1590
Weight [g]: 158.6
Housing: threaded type
Mounting: flush mountable
Dimensions [mm]: M30 x 1.5 / L = 70
Thread designation: M30 x 1.5
Materials: stainless steel (1.4404 / 316L); PEI; lock nuts: stainless steel
Full-metal housing: yes
Display: switching status 4 x 90° LED, yellow
switching status: 4 x 90° LED, yellow
Accessories (supplied): lock nuts: 2
Remarks: Note: for use in hazardous areas A fuse must be connected between the current source and the unit. (40 mA time lag, to EN 60127-2) The fuse must be inserted in the circuit L+ outside the hazardous areas.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.16 kg
Length: 0.00 m
Width: 0.00 m