II001A
Inductive sensor. IIA2015-ABOA/6M/3D
For applications in hazardous areas. With combined AC/DC output stage. Large operating voltage range. Two-wire technology. Robust metal housing for use in harsh industrial environments
Output function: | normally open |
Sensing range [mm]: | 15 |
Housing: | threaded type |
Dimensions [mm]: | M30 x 1.5 / L = 81 |
Installation: | use in hazardous areas only with installed protective cover |
Operating voltage [V]: | 20...250 AC/DC |
Protection class: | II |
Reverse polarity protection: | yes |
Output function: | normally open |
Max. voltage drop switching output DC [V]: | 6 |
Max. voltage drop switching output AC [V]: | 6.5 |
Minimum load current [mA]: | 5 |
Max. leakage current [mA]: | 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) |
Permanent current rating of switching output AC [mA]: | 150 |
Permanent current rating of switching output DC [mA]: | 100 |
Short-time current rating of switching output [mA]: | 2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz]: | 25 |
Switching frequency DC [Hz]: | 50 |
Notes on switching frequency: | only for resistive loads; 2 Hz for utilisation category AC-140 |
Short-circuit protection: | no |
Overload protection: | no |
Sensing range [mm]: | 15 |
Real sensing range Sr [mm]: | 15 ± 10 % |
Operating distance [mm]: | 0...12.1 |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
Hysteresis [% of Sr]: | 1...20 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -20...60 |
Protection: | IP 67 |
ATEX marking: | II 3D Ex tc IIIC T80°C Dc X |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 3 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 3 V IEC 60255-5 1 kV line to line, Ri: 500 Ohm EN 55011 emission class B |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 3 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 3 V |
IEC 60255-5: | 1 kV line to line, Ri: 500 Ohm |
EN 55011 emission: | class B |
MTTF [years]: | 607 |
Weight [K40]: | 489 |
Housing: | threaded type |
Mounting: | non-flush mountable |
Dimensions [mm]: | M30 x 1.5 / L = 81 |
Thread designation: | M30 x 1.5 |
Materials: | brass white bronze coated; sensing face: PBT; lock nuts: brass white bronze coated; Protective cover: PA |
Display: | switching status 1 x LED, yellow |
switching status: | 1 x LED, yellow |
Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
Accessories (supplied): | lock nuts: 3 Protective cover: 1 |
Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. |
Pack quantity: | 1 pcs. |
Connection: | Cable: 6 m, PVC; 2 x 0.50 mm² |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.49 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |