Wide operating temperature range. Temperature shock resistant even in case of frequent temperature fluctuations. Robust stainless steel housing for use in the food and beverage industry. Resistant to high-pressure cleaning with aggressive cleaning agents. High protection rating for the requirements of harsh industrial environments
| Electrical design: | PNP/NPN |
| Output function: | normally open |
| Sensing range [mm]: | 12 |
| Housing: | threaded type |
| Dimensions [mm]: | M18 x 1 / L = 81 |
| Special feature: | Increased sensing range; Optical setting aid |
| Application: | regular cleaning processes |
| Operating voltage [V]: | 10...30 DC |
| Current consumption [mA]: | < 10 |
| Protection class: | II |
| Reverse polarity protection: | yes |
| Electrical design: | PNP/NPN |
| Output function: | normally open |
| Max. voltage drop switching output DC [V]: | 2.8 |
| Minimum load current [mA]: | 2; (only in 2-wire operation) |
| Max. leakage current [mA]: | 0.5; (only in 2-wire operation) |
| Permanent current rating of switching output DC [mA]: | 100 |
| Switching frequency DC [Hz]: | 300 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Sensing range [mm]: | 12 |
| Real sensing range Sr [mm]: | 12 ± 10 % |
| Operating distance [mm]: | 0...9.7 |
| Increased sensing range: | yes |
| Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr]: | 1...20 |
| Switch point drift [% of Sr]: | -10...10 |
| Ambient temperature [°C]: | 0...100 |
| Protection: | IP 68; IP 69K; ("COP") |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV line to line, Ri: 2 Ohm EN 61000-4-6 HF conducted 10 V EN 55011 class B |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5 kV line to line, Ri: 2 Ohm |
| EN 61000-4-6 HF conducted: | 10 V |
| EN 55011: | class B |
| MTTF [years]: | 1359 |
| UL approval: | Ta 0...40 °C Enclosure type Type 1 voltage supply Limited Voltage/Current File number UL E174191 |
| Ta: | 0...40 °C |
| Enclosure type: | Type 1 |
| voltage supply: | Limited Voltage/Current |
| File number UL: | E174191 |
| Weight [g]: | 388.5 |
| Housing: | threaded type |
| Mounting: | non-flush mountable |
| Dimensions [mm]: | M18 x 1 / L = 81 |
| Thread designation: | M18 x 1 |
| Materials: | stainless steel (1.4404 / 316L); sensing face: PEEK |
| Display: | switching status 4 x 90° LED, yellow setting aid 1 x LED, red |
| switching status: | 4 x 90° LED, yellow |
| setting aid: | 1 x LED, red |
| Optical setting aid: | yes |
| Accessories (supplied): | lock nuts: 2 |
| Remarks: | suitable for PLC type 1 according to IEC 61131-2 |
| Pack quantity: | 1 pcs. |
| Connection: | Cable: 10 m, PVC, Ø 4.9 mm; 3 x 0.34 mm² |
| ECCN: | |
| Country of Origin: | RO |
| EAN: | |
| Weight: | 0.39 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |