IGM207
Inductive sensor. IGK3012-BPKG/M/60V/6M/ZH
Electrical design: | PNP |
Output function: | normally open |
Sensing range [mm]: | 12 |
Housing: | threaded type |
Dimensions [mm]: | M18 x 1 / L = 81 |
Special feature: | Increased sensing range |
Application: | Use in mobile and harsh applications |
Operating voltage [V]: | 10...60 DC |
Current consumption [mA]: | < 10 |
Protection class: | II |
Reverse polarity protection: | yes |
Electrical design: | PNP |
Output function: | normally open |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 200 |
Switching frequency DC [Hz]: | 200 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Sensing range [mm]: | 12 |
Real sensing range Sr [mm]: | 12 ± 10 % |
Operating distance [mm]: | 0...9.72 |
Increased sensing range: | yes |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 |
Hysteresis [% of Sr]: | 1...20 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -40...85 |
Protection: | IP 67; IP 69K |
EMC: | automotive area noise emission and noise interference according to the automotive directive 95/54/EC E1 type approval noise immunity according to DIN ISO 11452-2 100 V/m conducted interference acc. to ISO 7637-2 pulse 1 2 3a 3b 4 5 severity level IV IV IV IV IV IV failure criterion C C A A A C EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV mains line to line EN 61000-4-6 HF conducted 10 V EN 55011 class B |
noise emission and noise interference according to the automotive directive 95/54/EC: | E1 type approval |
noise immunity according to DIN ISO 11452-2: | 100 V/m |
pulse: | 1 2 3a 3b 4 5 |
severity level: | IV IV IV IV IV IV |
failure criterion: | C C A A A C |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5 kV mains line to line |
EN 61000-4-6 HF conducted: | 10 V |
EN 55011: | class B |
Vibration resistance: | EN 60068-2-6 Fc 20 g (10...3000 Hz) / -20...50 °C 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
EN 60068-2-6 Fc: | 20 g (10...3000 Hz) / -20...50 °C |
Shock resistance: | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
EN 60068-2-27 Ea: | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
Continuous shock resistance: | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
EN 60068-2-27: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
Salt spray test: | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
EN 60068-2-52 Kb: | severity level 5 (4 test cycles) |
MTTF [years]: | 1112 |
UL approval: | Ta 0...40 °C Enclosure type Type 1 voltage supply Hazardous voltage File number UL E174191 |
Ta: | 0...40 °C |
Enclosure type: | Type 1 |
voltage supply: | Hazardous voltage |
File number UL: | E174191 |
Weight [K40]: | 301 |
Housing: | threaded type |
Mounting: | non-flush mountable |
Dimensions [mm]: | M18 x 1 / L = 81 |
Thread designation: | M18 x 1 |
Materials: | housing: stainless steel; sensing face: LCP natural; lock nuts: brass |
Display: | switching status 4 x 90° LED, yellow |
switching status: | 4 x 90° LED, yellow |
Accessories (supplied): | lock nuts: 2 |
Pack quantity: | 1 pcs. |
Connection: | Cable: 6 m, PUR, Ø 5.4 mm; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.30 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |