Inductive sensor. IFK2007-BRKG/M/60V/1,4M/HH
| Electrical design: | PNP/NPN |
| Output function: | normally closed |
| Sensing range [mm]: | 7 |
| Housing: | threaded type |
| Dimensions [mm]: | M12 x 1 / L = 79 |
| Special feature: | Increased sensing range |
| Application: | Use in mobile and harsh applications |
| Operating voltage [V]: | 10...60 DC |
| Protection class: | II |
| Reverse polarity protection: | yes |
| Electrical design: | PNP/NPN |
| Output function: | normally closed |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Minimum load current [mA]: | 2 |
| Max. leakage current [mA]: | 0.5 |
| Permanent current rating of switching output DC [mA]: | 200 |
| Switching frequency DC [Hz]: | 400 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Sensing range [mm]: | 7 |
| Real sensing range Sr [mm]: | 7 ± 10 % |
| Operating distance [mm]: | 0...5.67 |
| Increased sensing range: | yes |
| Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
| Hysteresis [% of Sr]: | 1...20 |
| Switch point drift [% of Sr]: | -10...10 |
| Ambient temperature [°C]: | -40...85 |
| Protection: | IP 67; IP 69K |
| EMC: | automotive area noise emission and noise interference according to the automotive directive 95/54/EC E1 type approval noise immunity according to DIN ISO 11452-2 100 V/m conducted interference acc. to ISO 7637-2 pulse 1 2 3a 3b 4 5 severity level IV IV IV IV IV IV failure criterion C C A A A C EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV mains line to line EN 61000-4-6 HF conducted 10 V EN 55011 class B |
| noise emission and noise interference according to the automotive directive 95/54/EC: | E1 type approval |
| noise immunity according to DIN ISO 11452-2: | 100 V/m |
| pulse: | 1 2 3a 3b 4 5 |
| severity level: | IV IV IV IV IV IV |
| failure criterion: | C C A A A C |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5 kV mains line to line |
| EN 61000-4-6 HF conducted: | 10 V |
| EN 55011: | class B |
| Vibration resistance: | EN 60068-2-6 Fc 20 g (10...3000 Hz) / -20...50 °C 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
| EN 60068-2-6 Fc: | 20 g (10...3000 Hz) / -20...50 °C |
| Shock resistance: | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea: | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| Continuous shock resistance: | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| EN 60068-2-27: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test: | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb: | severity level 5 (4 test cycles) |
| MTTF [years]: | 695 |
| Weight [K40]: | 86.8 |
| Housing: | threaded type |
| Mounting: | non-flush mountable |
| Dimensions [mm]: | M12 x 1 / L = 79 |
| Thread designation: | M12 x 1 |
| Materials: | housing: stainless steel; sensing face: PBT; LED window: PEI; lock nuts: brass |
| Display: | switching status 4 x 90° LED, yellow |
| switching status: | 4 x 90° LED, yellow |
| Accessories (supplied): | lock nuts: 2 |
| Pack quantity: | 1 pcs. |
| Connection: | Cable: 1.4 m, PUR; 2 x 0.5 mm² |
| ECCN: | |
| Country of Origin: | RO |
| EAN: | |
| Weight: | 0.09 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |