Ifm IF0309

Inductive sensor. IFK2004-AROA/SL/LS100-AK RT

On Request. Please send us an email to inquire the price and avaliability.
"ucnguBrctvdgcxgt0eqo"

Description

With combined AC/DC output stage. Large operating voltage range. Two-wire technology. Robust metal housing for use in harsh industrial environments. For a precise position detection on machines

Technical parameters

Output function: normally open
Sensing range [mm]: 4
Housing: threaded type
Dimensions [mm]: M12 x 1
Frequency AC [Hz]: 47...63
Operating voltage [V]: 20...140 AC / 10...140 DC
Protection class: I
Reverse polarity protection: no
Output function: normally open
Max. voltage drop switching output DC [V]: 5
Max. voltage drop switching output AC [V]: 5
Minimum load current [mA]: 5
Max. leakage current [mA]: 0.8
Permanent current rating of switching output AC [mA]: 200
Permanent current rating of switching output DC [mA]: 200
Short-time current rating of switching output [mA]: 900; (20 ms / 0,5 Hz)
Switching frequency AC [Hz]: 25
Switching frequency DC [Hz]: 90
Short-circuit proof: no
Overload protection: no
Sensing range [mm]: 4
Real sensing range Sr [mm]: 4 ± 10 %
Operating distance [mm]: 0...3.25
Correction factor: steel: 1 / stainless steel: 0.7 / brass: 0.45 / aluminium: 0.4 / copper: 0.33
Hysteresis [% of Sr]: 3...15
Switch point drift [% of Sr]: -10...10
Ambient temperature [°C]: -25...70
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN61000-4-3 HF radiated 3 V/m EN 61000-4-4 Burst 2 kV EN 6100-4-6 HF conducted 3 V EN 55011 class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN61000-4-3 HF radiated: 3 V/m
EN 61000-4-4 Burst: 2 kV
EN 6100-4-6 HF conducted: 3 V
EN 55011: class B
MTTF [years]: 1257
UL approval: Ta 0...40 °C Enclosure type Type 1 voltage supply Hazardous voltage File number UL E174191
Ta: 0...40 °C
Enclosure type: Type 1
voltage supply: Hazardous voltage
File number UL: E174191
Weight [K40]: 28.2
Housing: threaded type
Mounting: non-flush mountable
Dimensions [mm]: M12 x 1
Thread designation: M12 x 1
Materials: brass white bronze coated; sensing face: PC
Tightening torque [Nm]: A = 4 mm: 3,5 Nm; B: 5 Nm
Display: switching status 1 x LED, red
switching status: 1 x LED, red
Required protection: miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting
Accessories (supplied): lock nuts: 2
Remarks: Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity: 1 pcs.

Logistic parameters

ECCN:
Country of Origin: RO
EAN:
Weight: 0.03 kg
Length: 0.00 m
Width: 0.00 m
Height: 0.00 m