IF0300
Inductive sensor. IFA2004-ABOW/SL/BS-400B
With AC output for use in AC power mains. Wide AC operating voltage range. Robust metal housing for use in harsh industrial environments. Clearly visible indication of the switching status. For a precise position detection on machines
Output function: | normally open |
Sensing range [mm]: | 4 |
Housing: | threaded type |
Dimensions [mm]: | M12 x 1 |
Frequency AC [Hz]: | 45...65 |
Operating voltage [V]: | 20...250 AC |
Protection class: | I |
Reverse polarity protection: | no |
Output function: | normally open |
Max. voltage drop switching output AC [V]: | 8.5 |
Minimum load current [mA]: | 8 |
Max. leakage current [mA]: | 2 |
Permanent current rating of switching output AC [mA]: | 200; (250 (...50 °C)) |
Short-time current rating of switching output [mA]: | 900; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz]: | 25 |
Short-circuit proof: | no |
Overload protection: | no |
Sensing range [mm]: | 4 |
Real sensing range Sr [mm]: | 4 ± 10 % |
Operating distance [mm]: | 0...3.24 |
Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
Hysteresis [% of Sr]: | 3...15 |
Switch point drift [% of Sr]: | -10...10 |
Ambient temperature [°C]: | -25...80 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 3 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 3 V EN 55011 class B |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 3 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 3 V |
EN 55011: | class B |
MTTF [years]: | 932 |
Weight [K40]: | 33.1 |
Housing: | threaded type |
Mounting: | non-flush mountable |
Dimensions [mm]: | M12 x 1 |
Thread designation: | M12 x 1 |
Materials: | brass white bronze coated; sensing face: PBT natural; LED window: PBT natural; Nuts: brass white bronze coated |
Tightening torque [Nm]: | A = 3 mm: 3,5 Nm; B: 7 Nm |
Length L [mm]: | 77 |
Display: | switching status 1 x LED, red |
switching status: | 1 x LED, red |
Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
Accessories (supplied): | lock nuts: 2 |
Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Country of Origin: | RO |
EAN: | |
Weight: | 0.03 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |