Magnetic-field immune for welding applications. Resistant to weld splatter thanks to Duroplast lid and PTFE coating. Long sensing range for high uptime. Correction factor 1: Constant sensing range on all metals. Very high switching frequency

Technical parameters

Electrical design: PNP
Output function: normally open
Sensing range [mm]: 6
Housing: threaded type
Dimensions [mm]: M8 x 1 / L = 40
Special feature: Gold-plated contacts; Increased sensing range; Correction factor K = 1; Magnetic-field immune; anti-spatter
Application: Use in welding applications
Magnetic-field immune: yes
Max. magnetic field immunity [mT]: 300
Operating voltage [V]: 10...30 DC
Current consumption [mA]: < 20
Protection class: III
Reverse polarity protection: yes
Electrical design: PNP
Output function: normally open
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: 2000
Short-circuit protection: yes
Overload protection: yes
Sensing range [mm]: 6
Real sensing range Sr [mm]: 6 ± 10 %
Operating distance [mm]: 0...4.86
Increased sensing range: yes
Correction factor: steel: 1 / stainless steel: 1 / brass: 1 / aluminium: 1 / copper: 1
Hysteresis [% of Sr]: 3...15
Switch point drift [% of Sr]: -10...10
Correction factor K = 1: yes
Ambient temperature [°C]: -40...85
Protection: IP 65; IP 66; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on)
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
EN 55011: class B
Vibration resistance: EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
EN 60068-2-6 Fc: 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance: EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance: EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature change: EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
EN 60068-2-14 Na: TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
Salt spray test: EN 60068-2-52 Kb severity level 5 (4 test cycles)
EN 60068-2-52 Kb: severity level 5 (4 test cycles)
MTTF [years]: 544
UL approval: Ta -25...80 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL Approval no. A011 File number UL E174191
Ta: -25...80 °C
Enclosure type: Type 1
voltage supply: Limited Voltage/Current
UL Approval no.: A011
File number UL: E174191
Weight [g]: 15.7
Housing: threaded type
Mounting: non-flush mountable
Dimensions [mm]: M8 x 1 / L = 40
Thread designation: M8 x 1
Materials: stainless steel (1.4404 / 316L) anti-spatter; sensing face: LCP black; LED window: PEI; lock nuts: brass anti-spatter
Display: switching status 4 x 90° LED, yellow
switching status: 4 x 90° LED, yellow
Accessories (supplied): lock nuts: 2
Pack quantity: 1 pcs.
Connection: Connector: 1 x M8; Contacts: gold-plated

Logistic parameters

ECCN:
Country of Origin: DE
EAN:
Weight: 0.02 kg
Length: 0.00 m