GM701S
Fail-safe inductive sensor. GIMC-4030-US/2OSSD
For ensuring machine safety. Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849. No special actuator for electronic fail-safe sensors required. Connection to safety PLC and safe evaluation units
| Electrical design: | PNP |
| Output function: | 2 x OSSD (A1 and A2) |
| Enable zone [mm]: | 10...15 |
| Housing: | rectangular |
| Dimensions [mm]: | 40 x 40 x 66 |
| Special feature: | Gold-plated contacts |
| Type of operation: | continuous operation (maintenance-free) |
| Application: | industrial application |
| Operating voltage [V]: | 19.2...30 DC |
| Rated insulation voltage [V]: | 30 |
| Current consumption [mA]: | < 15 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Max. power-on delay time [ms]: | 5000 |
| Electrical design: | PNP |
| Output function: | 2 x OSSD (A1 and A2) |
| Max. voltage drop switching output DC [V]: | 2.5; (100 mA) |
| Output data: | Interface type C class 0 |
| Output voltage at 24 V: | compatible with EN 61131-2 inputs type 1, 2, 3 |
| Short-circuit protection: | yes |
| Max. capacitive load CL_max [nF]: | 20 |
| Enable zone [mm]: | 10...15 |
| Safe switching-off distance s(ar) [mm]: | 30 |
| Response time to safety request [ms]: | 50 |
| Response time when approaching the enable zone [ms]: | 200 |
| Risk time (response time for safety-related faults) [ms]: | 100 |
| Applications: | class C to EN 60654-1 weatherproof application |
| Ambient temperature [°C]: | -25...70 |
| Note on ambient temperature: | operational life ≤ 87600 h |
| Ambient temperature [°C]: | 10...40 |
| Note on ambient temperature: | operational life ≤ 175200 h |
| Rate of temperature change [K/min]: | 0.5 |
| Max. relative air humidity [%]: | briefly: 5...95 %; permanent: 5...70 % |
| Air pressure [kPa]: | 80...106 |
| Max. height above sea level [m]: | 2000 |
| Ionising radiation: | not permissible |
| Salt spray: | no |
| Protection: | IP 65; IP 67 |
| EMC: | IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-3 EN 61000-4-2 ESD 6 kV CD / 8 kV AD EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 61000-4-8 30 A/m EN 55011 class B |
| EN 61000-4-2 ESD: | 6 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 20 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| EN 61000-4-8: | 30 A/m |
| EN 55011: | class B |
| Shock resistance: | IEC 60947-5-2 |
| Vibration resistance: | IEC 60947-5-2 |
| UL approval: | Ta -25...70 °C Enclosure type Type 1 voltage supply Limited Voltage/Current File number UL E174191 |
| Ta: | -25...70 °C |
| Enclosure type: | Type 1 |
| voltage supply: | Limited Voltage/Current |
| File number UL: | E174191 |
| ISO 13849-1: | category 3, PL e |
| IEC 61508: | SIL 3 |
| IEC 62061: | SIL cl 3 |
| Mission time TM [h]: | ≤ 175200 |
| Mission time TM (additional indication): | 20 years |
| Safety-related reliability PFHD [1/h]: | 1E-08 |
| Weight [g]: | 342.5 |
| Housing: | rectangular |
| Mounting: | non-flush mountable |
| Dimensions [mm]: | 40 x 40 x 66 |
| Materials: | PPE; diecast zinc |
| Display: | operation 1 x LED, green signal 1 x LED, yellow |
| operation: | 1 x LED, green |
| signal: | 1 x LED, yellow |
| Remarks: | Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range. (FE360 = ST37K) 45x45x1 mm |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Country of Origin: | DE |
| EAN: | |
| Weight: | 0.34 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |