Fail-safe inductive sensor. GIFA4004-2PS/SIL2/V4A/US
For ensuring machine safety. Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849. No special actuator for electronic fail-safe sensors required. Connection to safety PLC, safe AS-i modules or safe evaluation units
Electrical design: | PNP |
Output function: | 2 x OSSD (A1 and A2) |
Enable zone [mm]: | 0.5...4 |
Housing: | threaded type |
Dimensions [mm]: | M12 x 1 / L = 70 |
Special feature: | Gold-plated contacts |
Type of operation: | continuous operation (maintenance-free) |
Application: | industrial application |
Operating voltage [V]: | 19.2...30 DC |
Rated insulation voltage [V]: | 30 |
Current consumption [mA]: | < 20 |
Protection class: | III |
Reverse polarity protection: | yes |
Max. power-on delay time [ms]: | 1000 |
Electrical design: | PNP |
Output function: | 2 x OSSD (A1 and A2) |
Max. voltage drop switching output DC [V]: | 2.5; (30 mA) |
Permanent current rating of switching output DC [mA]: | 100 |
Output data: | Interface type C class 1 |
Output voltage at 24 V: | compatible with EN 61131-2 inputs type 1, 2 |
Short-circuit protection: | yes |
Overload protection: | no |
Max. capacitive load CL_max [nF]: | 20 |
Enable zone [mm]: | 0.5...4 |
Safe switching-off distance s(ar) [mm]: | 6 |
Response time to safety request [ms]: | 1 |
Response time when approaching the enable zone [ms]: | 1 |
Risk time (response time for safety-related faults) [ms]: | 20 |
Applications: | class C to EN 60654-1 weatherproof application |
Ambient temperature [°C]: | -25...70 |
Note on ambient temperature: | operational life ≤ 87600 h |
Ambient temperature [°C]: | 10...40 |
Note on ambient temperature: | operational life ≤ 175200 h |
Rate of temperature change [K/min]: | 0.5 |
Max. relative air humidity [%]: | briefly: 5...95 %; permanent: 5...70 % |
Air pressure [kPa]: | 80...106 |
Max. height above sea level [m]: | 2000 |
Ionising radiation: | not permissible |
Salt spray: | no |
Protection: | IP 65; IP 67 |
EMC: | IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-3 EN 61000-4-2 ESD 6 kV CD / 8 kV AD EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 61000-4-8 30 A/m EN 55011 class B |
EN 61000-4-2 ESD: | 6 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 20 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
EN 61000-4-8: | 30 A/m |
EN 55011: | class B |
Shock resistance: | IEC 60947-5-2 |
Vibration resistance: | IEC 60947-5-2 |
UL approval: | Ta -25...70 °C Enclosure type Type 1 voltage supply Limited Voltage/Current File number UL E174191 |
Ta: | -25...70 °C |
Enclosure type: | Type 1 |
voltage supply: | Limited Voltage/Current |
File number UL: | E174191 |
ISO 13849-1: | category 2, PL d |
IEC 61508: | SIL 2 |
IEC 62061: | SIL cl 2 |
Mission time TM [h]: | ≤ 175200 |
Mission time TM (additional indication): | 20 years |
Safety-related reliability PFHD [1/h]: | 1.0E-07 |
Weight [g]: | 105.5 |
Housing: | threaded type |
Mounting: | non-flush mountable |
Dimensions [mm]: | M12 x 1 / L = 70 |
Thread designation: | M12 x 1 |
Materials: | stainless steel (1.4404 / 316L); PBT |
Display: | operation 1 x LED, green signal 1 x LED, yellow |
operation: | 1 x LED, green |
signal: | 1 x LED, yellow |
Accessories (supplied): | lock nuts: 2 |
Remarks: | Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range. (FE360 = ST37K) 12x12x1 mm |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.11 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |