AL1331
IO-Link master with EtherCAT interface. IO-Link Master DL EC 4P IP69K
Separation between automation network and IT network. For connection of up to four IO-Link devices. Reliable transmission of machine data, process parameters and diagnostic data to the controller. With EtherCat interface and separate MQTT JSON interface. High protection rating for the requirements of the food and beverage industry
Application: | hygienic systems; I/O modules for field applications |
Daisy-chain function: | fieldbus interface |
Operating voltage [V]: | 20...28 DC; (US; to SELV/PELV) |
Current consumption [mA]: | 300...3900; (US) |
Protection class: | III |
Max. current load total [A]: | 3.6 |
Total number of inputs and outputs: | 8; (configurable) |
Number of inputs and outputs: | Number of digital inputs: 8; Number of digital outputs: 4 |
Number of digital inputs: | 8; (IO-Link Port Class A: 4 x 2) |
Switching level high [V]: | 11...28 |
Switching level low [V]: | 0...5 |
Digital inputs protected against short circuits: | yes |
Number of digital outputs: | 4; (IO-Link Port Class A: 4 x 1) |
Max. current load per output [mA]: | 300 |
Short-circuit proof: | yes |
Communication interface: | Ethernet; IO-Link |
Transmission standard: | 10Base-T; 100Base-TX |
Transmission rate: | 10; 100 |
Protocol: | EtherCAT |
Factory settings: | MAC address: see type label |
Transmission standard: | 10Base-T; 100Base-TX |
Transmission rate: | 10; 100 |
Protocol: | MQTT JSON |
Factory settings: | IP address: 169.254.x.x subnet mask: 255.255.0.0 gateway IP address: 0.0.0.0 MAC address: see type label |
Note on interfaces: | Secure protocol; HTTPS |
Transmission type: | COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud) |
IO-Link revision: | 1.1 |
Number of ports class A: | 4 |
Ambient temperature [°C]: | -25...60 |
Storage temperature [°C]: | -25...85 |
Max. relative air humidity [%]: | 90 |
Protection: | IP 65; IP 66; IP 67; IP 69K; (operation with stainless steel protective caps: IP 69K) |
Degree of soiling: | 2 |
EMC: | EN 61000-6-2 EN 61000-6-4 |
Shock resistance: | DIN EN 60068-2-27 |
Vibration resistance: | DIN EN 60068-2-64 2009-04 DIN EN 60068-2-6 2008-10 |
MTTF [years]: | 90 |
Weight [g]: | 283 |
Materials: | housing: PA grey; socket: stainless steel (1.4404 / 316L) |
Accessories (supplied): | Protective cap: 1 x M12, stainless steel, E12542 |
Remarks: | For further information please see the operating instructions. |
Pack quantity: | 1 pcs. |
EtherCAT X21, X22: | Connector: M12 |
IO-Link Port Class A X01...X04: | Connector: M12 |
X31: | Connector: M12 |
ECCN: | |
Country of Origin: | PL |
EAN: | |
Weight: | 0.28 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |