AC535A
AS-Interface ClassicLine module with quick mounting technology. ClassicL 4DI-Y 4DO-Y II 3D
Easy toolless installation and wiring thanks to quick mounting technology. Three freely selectable directions of the flat cable. Clearly visible powerful LEDs for displaying operation, status and function. For applications in hazardous areas. Robust M12 connectors for connecting sensors and actuators
Application: | only for operation with AS-i masters with the profile M4 |
Operating voltage [V]: | 26.5...31.6 DC |
Max. current consumption from AS-i [mA]: | 250 |
Max. current load total [A]: | 2 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital inputs: 4; Number of digital outputs: 4 |
Number of digital inputs: | 4 |
Input circuit of digital inputs: | PNP |
Sensor supply of the inputs: | AS-i |
Voltage supply [V]: | 18...30; (via flat cable) |
Max. total current rating of inputs [mA]: | 200 |
Input current High [mA]: | 6...10 |
Input current Low [mA]: | 0...2 |
Min. switching level high signal [V]: | 11 |
Digital inputs protected against short circuits: | yes |
Number of digital outputs: | 4 |
Circuit: | PNP |
Voltage range DC [V]: | 15...30; (to PELV; via flat cable) |
Max. current load per output [mA]: | 1000; (utilisation category DC-13 (control of electromagnets): 20 W (IEC 60947-5-1)) |
Short-circuit proof: | yes |
Electrically separated: | yes |
Ambient temperature [°C]: | -10...50 |
Protection: | IP 50 |
ATEX marking: | II 3D Ex tc IIIB T80°C Dc X IP50 |
EMC: | EN 50295 IEC 61000-6-2 |
MTTF [years]: | 155 |
AS-i version: | 3.0 |
AS-i addressing: | addressing socket |
Extended addressing mode possible: | yes |
AS-i profile: | S-7.A.7 |
AS-i I/O configuration [hex]: | 7 |
AS-i ID code [hex]: | A.7 |
AS-i certificate pending: | yes |
Assignment of the data bits: | data bit D0 D1 D2 D3 input 1 2 3 4 socket I-1/2 I-1/2 I-2 I-3/4 I-3/4 I-4 pin 4 2 4 4 2 4 Output 1 2 3 4 socket O-1/2 O-1/2 O2 O-3/4 O-3/4 O-4 pin 4 2 4 4 2 4 |
data bit: | D0 |
input: | 1 |
socket: | I-1/2 |
pin: | 4 |
Output: | 1 |
socket: | O-1/2 |
pin: | 4 |
Weight [g]: | 322 |
Type of mounting: | AS-i flat cables directly connectable |
Materials: | PA; piercing contacts: CuSn6 nickel-plated and tin-plated |
Display: | operation LED, green errors LED, red function LED, yellow |
operation: | LED, green |
errors: | LED, red |
function: | LED, yellow |
Accessories (supplied): | lower part |
Accessories (optional): | Protective cap: M12, E73004 Impact protection housing:, E7000A |
Remarks: | Mechanical protection has to be implemented. Otherwise the unit must be installed together with the impact protection housing (E7000A). Do not connect any of the following points to an external potential: I-, I+, I1, I2, I3, I4 The connections are electrically connected with the AS-i cable. Inputs and outputs must be electrically isolated. |
Pack quantity: | 1 pcs. |
Connection: | Connector: M12 |
Connection: | Connector: M12 |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.32 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |