AC2752
AS-Interface PCB module. PCB 4DI 4DO T C A/B
For installation in small housings, control cabinets and operator panels. Simple and fast wiring by means of screw terminals. Particularly space-saving design. For integration of mechanical switches into AS-i networks. AS-i connection for four control and signalling devices
Application: | only for operation with AS-i masters with the profile M4 |
Operating voltage [V]: | 18...31.6 DC |
Max. current consumption from AS-i [mA]: | 180; (without sensors: < 30 mA; inputs and outputs active: < 180 mA) |
Protection class: | III |
Max. current load total [A]: | 0.15; (total current for all outputs and sensor supply supplied from AS-i: 150 mA) |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital inputs: 4; Number of digital outputs: 4 |
Number of digital inputs: | 4 |
Input circuit of digital inputs: | PNP |
Sensor supply of the inputs: | AS-i |
Voltage supply [V]: | 18...30 |
Max. total current rating of inputs [mA]: | 150 |
Input current High [mA]: | 6...10 |
Input current Low [mA]: | 0...2 |
Min. switching level high signal [V]: | 11 |
Digital inputs protected against short circuits: | yes |
Number of digital outputs: | 4 |
Circuit: | PNP |
Voltage range DC [V]: | AS-i |
Max. current load per output [mA]: | 100; (utilisation category DC-13 (control of electromagnets): 2,5 W (IEC 60947-5-1)) |
Short-circuit proof: | yes |
Electrically separated: | yes |
Ambient temperature [°C]: | -25...55 |
Protection: | IP 20 |
EMC: | EN 50295 |
MTTF [years]: | 220 |
AS-i version: | 3.0 |
Extended addressing mode possible: | yes |
AS-i profile: | S-7.A.7 |
AS-i I/O configuration [hex]: | 7 |
AS-i ID code [hex]: | A.7 |
AS-i certificate: | 102301 |
Weight [g]: | 68 |
Type of mounting: | installation in a surface-mounted housing |
Dimensions [mm]: | 31.1 x 12 x 76.6 |
Materials: | housing: PC potted |
Display: | operation LED, green errors LED, red function LED, yellow |
operation: | LED, green |
errors: | LED, red |
function: | LED, yellow |
Remarks: | A watchdog function switches the outputs off if there is no communication on the AS-i line. Install the unit so that exposed parts cannot be touched. Installation in a surface-mounted housing with the dimensions of 68 x 136 x 53 mm (LxWxH), e.g. Schneider Electric Harmony, XALD03, XALD04 Do not connect any of the following points to an external potential: 0-, I+, I1, I2, I3, I4 The connections are electrically connected with the AS-i cable. can be used up to a height of 2000 metres above sea level |
Pack quantity: | 1 pcs. |
ECCN: | |
Country of Origin: | DE |
EAN: | |
Weight: | 0.07 kg |
Length: | 0.00 m |
Width: | 0.00 m |
Height: | 0.00 m |