109658
RKT 5-259/3 M
RKT 5-259 - M12 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 5-pin, A-coded, translucent body, 50 V AC / 60 V DC, 4 A; PUR orange cable, 5-wires, 0.50 mm²
M12 Micro Actuator/sensor cordset, single-ended, 5-poles, female straight connector with self-locking thread and orange PUR halogen-free welding spark proof molded cable. M12 Standard Sensor/Actuator Single-Ended Cordset: Female, straight, 5-pin, A-coded, translucent body, 50 V AC / 60 V DC, 4 A; PUR orange cable, 5-wires, 0.50 mm²
| brown: | white |
| Product Family:: | Sensor / Actuator Connectors |
| Product Sub Family:: | M12 Standard |
| Brand:: | Lumberg Automation |
| Connector Type:: | Cordset, single ended |
| Type of Contact / Gender:: | Female |
| Connector Design:: | Straight |
| Number of Pins:: | 5 |
| Coding:: | A |
| Shielding:: | Unshielded |
| Attachment Type:: | Coupling Nut |
| Rated Voltage:: | 60 V |
| Rated Voltage (UL):: | 30 V AC/DC |
| Rated Impulse Voltage:: | 1.5 kV |
| Operating Voltage:: | 50 V AC / 60 V DC |
| Rated Current*:: | 4 A |
| Rated Current (UL)*:: | 4 A |
| Contact Resistance:: | ≤ 10 mOhm |
| Insulation Resistance:: | ˃ 10^9 Ohm |
| Mating Cycles:: | ≤ 100 |
| Ambient Temperature (Operation)*:: | - 40 °C - + 90 °C |
| Operating Temperature (UL):: | max. + 50 °C |
| Protection Degree / IP Rating**:: | IP65, IP67, IP68 (1 m / 24 h), IP69K |
| Design Standard:: | IEC 61076-2-101 |
| Pollution Degree:: | 3 acc. to DIN EN 60664-1 (VDE 0110-1) |
| Overvoltage Category:: | III acc. to DIN EN 60664-1 (VDE 0110-1) |
| Contact Base Material:: | CuSn |
| Contact Plating:: | Cu/Au |
| Contact Bearer Material:: | TPU |
| Contact Bearer Color:: | Orange |
| Flammability Class (Contact Bearer):: | UL 94 HB |
| Molded Body Material:: | TPU |
| Molded Body Color:: | Translucent |
| Flammability Class (Molded Body):: | UL 94 HB |
| Attachment Material:: | CuZn |
| Attachment Plating:: | Nickel-plated |
| O-Ring Material:: | FKM, green |
| Fastening Torque (Attachment):: | M 12x1: (50-60) Ncm, hand-tight |
| Cable Number:: | 259 |
| Conductor Size:: | 0.50 mm² |
| Number of Wires:: | 5 |
| Minimal Bending Radius (Fixed Inst):: | ˃ 5 x D |
| Minimal Bending Radius (Flexible Inst):: | ˃ 10 x D |
| Cycles (Bending):: | ˃ 5 M |
| Cycles (Torsion):: | ˃ 5 M @ ± 360 °/1 m |
| Welding Resistance:: | Welding spark resistant |
| Conductor material:: | Cu |
| Cable Jacket Material:: | PUR |
| Cable Jacket Color:: | orange |
| Cable Diameter D:: | ø 5.50 ± 0.20 mm |
| Wire Insulation Material:: | PP |
| Insulated Wire Diameter:: | ø 1.50 mm |
| Ambient Temperature (Fixed Installation):: | - 50 °C - + 80 °C |
| Ambient Temperature (Flex Installation):: | - 25 °C - + 80 °C |
| Ambient Temperature (Drag Chain Inst):: | - 25 °C - + 60 °C |
| UL Cable Type:: | AWM: 20549 |
| Flammability Class (Cable Jacket):: | DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2 |
| Cable Characteristics:: | Free of lacquer wetting disturbing substances; Good microbes and hydrolysis resistance; Mainly plasticizer diffusion free; Exclusion of PVC and silicone; Seawater resistance; Coldness flexibilty |
| UL-File:: | E315587 |
| UL:: | UL 2238; cURus |
| RoHS Compliant:: | yes |
| Halogenfree:: | DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1 |
| Oil Resistance:: | VDE 0472-803 |
| Note Derating:: | Notice derating |
| Protection Degree / IP Rating Note:: | ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| Note:: | Do not connect or disconnect under load. |
| 11378: | RKT 5-259/2 M |
| 109658: | RKT 5-259/3 M |
| 11379: | RKT 5-259/5 M |
| 934636078: | RKT 5-259/7,5 M |
| 30091: | RKT 5-259/10 M |
| 934637151: | RKT 5-259/15 M |
| 934637152: | RKT 5-259/20 M |
| 15810: | RKT 5-259/25 M |
| ECCN: | |
| Country of Origin: | CZ |
| EAN: | |
| Weight: | 0.15 kg |
| Length: | 0.00 m |
| Width: | 0.00 m |
| Height: | 0.00 m |