239920
KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PApa. The FieldConnex. Diagnostic Gateway is the interface between stationary Advanced Diagnostic Modules (ADM) and the control system. It offers access to all ADM data in two ways: via Ethernet and the Diagnostic Manager software or via FOUNDATION Fieldbus H1 and DTM/EDD or both. The gateway configures itself and automatically detects the ADMs. The Diagnostic Manager automatically finds gateways on the same subnet. The setup of the diagnostic bus and all connected modules is automatic. This significantly simplifies engineering of FieldConnex. Advanced Diagnostics. Inputs for frequency, temperature, humidity, and NAMUR sensors and 2 relay contacts allow control of the control cabinet. The cabinet and physical layer diagnostics become easy-to-manage plant assets.
| Design / Mounting: | Motherboard based |
| Rated voltage: | 19.2 ... 35 V DC SELV/PELV |
| Rated current: | 210 ... 120 mA |
| Power dissipation: | max. 4.2 W |
| Fieldbus type: | FOUNDATION Fieldbus |
| Physical layer profile: | profile type 114 |
| ITK version: | 6 |
| Implementation: | resource block 1x RS function block 4x MDI, 1x MDO, 1x MAI, 1x DI transducer block 16x ADM TB, 1x IO TB |
| Firmware update: | Ethernet |
| Polarity: | polarity-sensitive |
| Rated voltage: | 9 ... 35 V SELV/PELV |
| Rated current: | 0 mA |
| Rated voltage: | max. 35 V SELV/PELV |
| Port: | 100 BASE-TX |
| Protocol: | TCP/IP and UDP/IP |
| Services: | ICMP , DHCP , AutoIP , HTTP |
| Connection type: | RJ-45 socket, 8-pin |
| Transfer rate: | 100 MBit/s |
| Connection: | only for the connection to protected circuits |
| Rated voltage: | max. 35 V |
| Number of Diagnostic Bus Channels: | 2 |
| Number of Diagnostic Modules/Channel: | 31 Using Ethernet Interface , 8 Using Fieldbus Interface |
| Termination: | integrated |
| Cable length/Channel: | 30 m |
| LED ERR: | red: Hardware fault |
| LED PWR: | green: Power on |
| Fault signal: | buzzer on |
| LINK/ACT: | yellow |
| CH1, CH2: | yellow: diagnostic bus activity |
| Input I, II: Input type: | selectable: Frequency input , NAMUR/mechanical contact |
| Frequency: Connection: | only passive load |
| Frequency: Rated voltage: | max. 35 V |
| Frequency: Input frequency: | 0.3 Hz to 1 kHz |
| Frequency: Pulse duration: | min. 50 µs |
| Frequency: Accuracy: | ± 1 % |
| Frequency: Cable length: | max. 30 m |
| Frequency: Line fault detection: | lead breakage , short-circuit |
| NAMUR: Sensor type: | NAMUR sensor according to IEC/EN 60947-5-6 |
| NAMUR: Connection: | only passive load |
| NAMUR: Rated voltage: | max. 35 V |
| NAMUR: Switching frequency: | 10 Hz |
| NAMUR: Cable length: | max. 30 m |
| NAMUR: Line fault detection: | lead breakage , short circuit |
| Input III, IV: Input type: | NAMUR/mechanical contact |
| NAMUR: Sensor type: | NAMUR sensor according to IEC/EN 60947-5-6 |
| NAMUR: Connection: | only passive load |
| NAMUR: Rated voltage: | max. 35 V |
| NAMUR: Switching frequency: | 10 Hz |
| NAMUR: Cable length: | max. 30 m |
| NAMUR: Line fault detection: | lead breakage , short circuit |
| Input V: Input type: | selectable: diagnostic bus CH 1 alarm input , NAMUR/mechanical contact |
| Alarm Input: Connection: | only passive load |
| Alarm Input: Rated voltage: | max. 35 V |
| Alarm Input: Cable length: | max. 30 m |
| Alarm Input: Line fault detection: | lead breakage , short circuit |
| NAMUR: Sensor type: | NAMUR sensor according to IEC/EN 60947-5-6 |
| NAMUR: Connection: | only passive load |
| NAMUR: Rated voltage: | max. 35 V |
| NAMUR: Switching frequency: | 10 Hz |
| NAMUR: Cable length: | max. 30 m |
| NAMUR: Line fault detection: | lead breakage , short circuit |
| Input VI: Input type: | selectable: diagnostic bus CH 2 alarm input , NAMUR/mechanical contact |
| Alarm Input: Connection: | only passive load |
| Alarm Input: Rated voltage: | max. 35 V |
| Alarm Input: Cable length: | max. 30 m |
| Alarm Input: Line fault detection: | lead breakage , short-circuit |
| NAMUR: Sensor type: | NAMUR sensor according to IEC/EN 60947-5-6 |
| NAMUR: Connection: | only passive load |
| NAMUR: Rated voltage: | max. 35 V |
| NAMUR: Switching frequency: | 10 Hz |
| NAMUR: Cable length: | max. 30 m |
| NAMUR: Line fault detection: | lead breakage , short circuit |
| Input VII, VIII: Input type: | selectable: Pt100 4-wire temperature input , NAMUR/mechanical contact |
| Temperature: Connection: | only passive load |
| Temperature: Rated voltage: | max. 35 V |
| Temperature: Measurement range: | -50 ... 90 °C (-58 ... 194 °F) |
| Temperature: Accuracy: | 1 K |
| Temperature: Measuring current: | 1 mA |
| Temperature: Lead resistance: | 4.2 Ω per line |
| Temperature: Cable length: | max. 30 m |
| Temperature: Line fault detection: | lead breakage , short-circuit |
| NAMUR: Sensor type: | NAMUR sensor according to IEC/EN 60947-5-6 |
| NAMUR: Connection: | only passive load |
| NAMUR: Rated voltage: | max. 35 V |
| NAMUR: Switching frequency: | 10 Hz |
| NAMUR: Cable length: | max. 30 m |
| NAMUR: Line fault detection: | lead breakage , short circuit |
| Humidity: Measurement range: | 0 ... 95 % RH |
| Humidity: Accuracy: | 2 % RH |
| Humidity: Resolution: | 0.04 % |
| Output I: Output type: | selectable: diagnostic bus CH 1 , relay , NO contact |
| Output I: Contact loading: | 250 V AC/ 6 A resistive load |
| Output I: Mechanical life: | 1 x 105 switching cycles |
| Output I: Response time: | turn-on time 7 ms , turn-off time 3 ms |
| Output I: Switching frequency: | 6 min-1 full load, 1200 min-1 without load |
| Output II: Output type: | selectable: diagnostic bus CH 2 , relay , NO contact |
| Output II: Contact loading: | 250 V AC/ 6 A resistive load |
| Output II: Mechanical life: | 1 x 105 switching cycles |
| Output II: Response time: | turn-on time 7 ms , turn-off time 3 ms |
| Output II: Switching frequency: | 6 min-1 full load, 1200 min-1 without load |
| Output III: Output type: | selectable: common alarm , volt-free contact , NC contact |
| Output III: Connection: | only for the connection to protected circuits |
| Output III: Voltage: | 50 V DC |
| Output III: Current: | max. 1 A |
| Output IV: Output type: | common alarm , buzzer |
| All circuits/FE: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Output I, II/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff |
| Ethernet/Supply: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Ethernet/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Fieldbus/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Diagnostic Bus/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 |
| Low voltage: Directive 73/23/EEC: | EN 61010-1:2010 |
| Galvanic isolation: | IEC 62103 |
| Electromagnetic compatibility: | NE 21 |
| Degree of protection: | IEC 60529 |
| Fieldbus standard: | IEC 61158-2 |
| Climatic conditions: | DIN IEC 721 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Ethernet: | IEEE 802.3 |
| Ambient temperature: | -40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | < 95 % non-condensing |
| Shock resistance: | 5 g 11 ms |
| Vibration resistance: | 1 g , 10 ... 150 Hz |
| Pollution degree: | max. 2, according to IEC 60664 |
| Corrosion resistance: | acc. to ISA-S71.04-1985, severity level G3 |
| Housing material: | Polycarbonate |
| Housing width: | see dimensions |
| Housing height: | see dimensions |
| Housing depth: | see dimensions |
| Degree of protection: | IP20 |
| Mass: | 500 g |
| Mounting: | DIN rail mounting |
| FOUNDATION Fieldbus: Connection: | For connection to circuits with safe limited voltage according to IEC 60079-11:2011, type of protection "ic" |
| FOUNDATION Fieldbus: Voltage Ui: | max. 35 V |
| Certificate: | TÜV 14 ATEX 115980 X |
| FOUNDATION Fieldbus: Marking: | Motherboard MB-FB-GT.AD.FF.IO II 3 G Ex nA nC IIC T4 Gc , Gateway II 3 G Ex nA IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 |
| IECEx approval: | IECEx TUN 14.0003X |
| Directive conformity: Approved for: | Motherboard Ex nA nC IIC T4 Gc , Gateway Ex nA IIC T4 Gc |
| Supplementary information: | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| ТН ВЭД: | |
| Страна происхождения: | Singapur |
| EAN: | 4050143063222 |
| Вес: | 0,79 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |