Pepperl+Fuchs 132964

KFD2-SR2-Ex2.W.SM

Standstill and Rotational Direction Monitor

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

This isolated barrier is used for intrinsic safety applications. 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa. This device is a standstill monitor that accepts input frequency pulses and triggers an output when the frequency drops below a preselected limit value. Two start-up override values are available. This unit can also be used to determine rotation direction. During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44. The device has LED status indicators for direction of rotation detection, limit detection, supply, and hardware faults. The device is easily configured by the use of DIP switches. If the device is operated via Power Rail, additionally a collective error message is available. For additional information, refer to www.pepperl-fuchs.com.

Технические характеристики

Signal type: Digital Input
Programming: via DIP switch and programmable
Safety Integrity Level (SIL): SIL 2
Connection: Power Rail or terminals 14+, 15-
Rated voltage: 20 ... 30 V DC
Power consumption: max. 1.5 W
Connection side: field side
Connection: Input I: terminals 1+, 2+, 3- ; Input II: terminals 4+, 5+, 6-
Rated values: acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current: approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis: 1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detection: breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Control input: sensor power supply approx. 8.2 V, impedance 1.2 kΩ
Pulse duration: > 200 µs for standstill monitoring, > 250 µs for rotation direction detecion
Connection side: control side
Connection: output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
Contact loading: 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Minimum switch current: 2 mA / 24 V DC
Energized/De-energized delay: approx. 20 ms / approx. 20 ms
Mechanical life: 107 switching cycles
Trip value: for standstill monitoring: 0.1 Hz; 0.5 Hz; 2 Hz; 10 Hz adjustable via DIP switch (S1 and S2)
Accuracy: 5 % (S3 = I), 30 % (S3 = II)
Start-up override: 5 seconds or 20 seconds, programmable
Frequency range: ≤ 2 kHz
Rotation direction detection: 90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µs
Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display elements: LEDs
Control elements: DIP-switch
Configuration: via DIP switches
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EU: EN 61010-1:2010
Electromagnetic compatibility: NE 21:2006
Degree of protection: IEC 60529:2001
Input: EN 60947-5-6:2000
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: approx. 150 g
Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: PTB 00 ATEX 2080
Low voltage: Marking: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Low voltage: Input: Ex ia
Low voltage: Voltage: 10.5 V
Low voltage: Current: 13 mA
Low voltage: Power: 34 mW (linear characteristic)
Supply: Maximum safe voltage: 253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Output: Contact loading: 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Output: Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.)
Fault indication output: Maximum safe voltage: 40 V DC (Attention! Um is no rated voltage.)
Certificate: TÜV 99 ATEX 1493 X
Fault indication output: Marking: II 3G Ex ec nC IIC T4 Gc
Output: Contact loading: 50 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Galvanic isolation: Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019
FM approval: FM certificate: FM19US0207X
FM approval: Control drawing: 116-0035
UL approval: E106378
FM approval: Control drawing: 116-0145
CSA approval: Control drawing: 116-0047
IECEx approval: IECEx certificate: IECEx PTB 11.0034 , IECEx TUN 19.0013X
IECEx approval: IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I Ex ec nC IIC T4 Gc
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Optional accessories: - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03)