AS-Interface pneumatic module
The VAA-4E2A-G1-ZE/P-S module features 4 inputs for the connection of 2- or 3-wire sensors and 2 pneumatic outputs with a high air flow rate for direct control of pneumatic drives in the field. 2 separate 3/2-way valves are integrated in the module. Both the valve and the sensors connected to the module are supplied via the bus cable. Pneumatic module. 4 inputs/2 pneumatic outputsfa. The sensors are connected to the module via M12 x 1-circular connectors; the outputs are connected to the pneumatic drive via standard hose plug-in connectors (LEGRIS LF 3000, 8 mm). Various bases are available for the module.The U-G1F (or U-G1FA) base provides the connection to the AS-Interface flat cable; the U-G1P base provides the connection to a round cable. It happens very frequently that output modules must be installed in series with the pneumatic module. If the outputs of the output modules are supplied with external power transferred via a flat cable, a suitable EEMS base (U-G1FF or U-G1FFA) must be used for the pneumatic module. In this case, VAA-4E2A-G1-ZE/P-S accesses the AS-Interface cable instead of the power supply cable. Note:. The slave address must be programmed before commissioning (default setting. Medium: Filtered (5 μm), oiled or unoiled compressed air (2 .. 8 bars). Warning:. Dangerous electric voltage can lead to electric shock and burns. The system must be disconnected from the power supply before the beginning of the works.
| Slave type: | Standard slave |
| MTTFd: | 44 a |
| Mission Time (TM): | 10 a |
| Diagnostic Coverage (DC): | 0 % |
| LED AS-i: | AS-Interface voltage; LED green |
| LED IN: | switching state (input); 4 LED yellow |
| LED OUT: | Switching state (output); 2 LED yellow |
| Rated operating voltage: | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current: | ≤ 45 mA (without sensors) ≤ 200 mA (complete) |
| Number/Type: | 2x 2 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply: | from AS-Interface |
| Current loading capacity: | ≤ 100 mA, short-circuit protected |
| Switching point: | OFF: ≤ 1.5 mA ON: ≥ 5 mA, ≥ 10 V |
| Number/Type: | 2 pneumatic outputs with separated 3/2-way valves |
| Venting guide: | Sinter filter |
| Compressed air: | 2 ... 8 bar, filtered (5 µm), oiled or unoiled compressed air |
| Air throughput: | 550 Nl/min at 6/0 bar 350 Nl/min at 6/5 bar Nl = Standard litre |
| Valve cross-section: | 5 mm |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 |
| Degree of protection: | EN 60529:2000 |
| AS-Interface: | EN 62026-2:2013 |
| Profile: | S-7.F |
| IO code: | 7 |
| ID code: | F |
| ID1 code: | F |
| ID2 code: | F |
| Data bits (function via AS-Interface): | input output |
| Electromagnetic compatibility: D0: | IN1 - |
| Electromagnetic compatibility: D1: | IN2 - |
| Electromagnetic compatibility: D2: | IN3 OUT3 |
| Electromagnetic compatibility: D3: | IN4 OUT4 |
| Parameter bits (programmable via AS-i): | function |
| Electromagnetic compatibility: P0: | not used |
| Electromagnetic compatibility: P1: | not used |
| Electromagnetic compatibility: P2: | not used |
| Electromagnetic compatibility: P3: | not used |
| Ambient temperature: | 0 ... 55 °C (32 ... 131 °F) |
| Storage temperature: | -20 ... 85 °C (-4 ... 185 °F) |
| Degree of protection: | IP65 according to EN 60529 |
| Connection: | cable piercing methos or terminals flat cable or standard round cable inputs: M12 x 1 quick disconnect outputs: plug-in hose connector (8 mm) |
| Mass: | approx. 200 g |
| Mounting: | DIN rail or screw mounting |
| ТН ВЭД: | |
| Страна происхождения: | DE |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |