Pepperl+Fuchs 130938

VAA-4E2A-G1-ZE/P-S

AS-Interface pneumatic module

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

The VAA-4E2A-G1-ZE/P-S module features 4 inputs for the connection of 2- or 3-wire sensors and 2 pneumatic outputs with a high air flow rate for direct control of pneumatic drives in the field. 2 separate 3/2-way valves are integrated in the module. Both the valve and the sensors connected to the module are supplied via the bus cable. Pneumatic module. 4 inputs/2 pneumatic outputsfa. The sensors are connected to the module via M12 x 1-circular connectors; the outputs are connected to the pneumatic drive via standard hose plug-in connectors (LEGRIS LF 3000, 8 mm). Various bases are available for the module.The U-G1F (or U-G1FA) base provides the connection to the AS-Interface flat cable; the U-G1P base provides the connection to a round cable. It happens very frequently that output modules must be installed in series with the pneumatic module. If the outputs of the output modules are supplied with external power transferred via a flat cable, a suitable EEMS base (U-G1FF or U-G1FFA) must be used for the pneumatic module. In this case, VAA-4E2A-G1-ZE/P-S accesses the AS-Interface cable instead of the power supply cable. Note:. The slave address must be programmed before commissioning (default setting. Medium: Filtered (5 μm), oiled or unoiled compressed air (2 .. 8 bars). Warning:. Dangerous electric voltage can lead to electric shock and burns. The system must be disconnected from the power supply before the beginning of the works.

Parametry techniczne

Slave type: Standard slave
MTTFd: 44 a
Mission Time (TM): 10 a
Diagnostic Coverage (DC): 0 %
LED AS-i: AS-Interface voltage; LED green
LED IN: switching state (input); 4 LED yellow
LED OUT: Switching state (output); 2 LED yellow
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface
Rated operating current: ≤ 45 mA (without sensors) ≤ 200 mA (complete)
Number/Type: 2x 2 inputs for 2- or 3-wire sensors (PNP), DC
Supply: from AS-Interface
Current loading capacity: ≤ 100 mA, short-circuit protected
Switching point: OFF: ≤ 1.5 mA ON: ≥ 5 mA, ≥ 10 V
Number/Type: 2 pneumatic outputs with separated 3/2-way valves
Venting guide: Sinter filter
Compressed air: 2 ... 8 bar, filtered (5 µm), oiled or unoiled compressed air
Air throughput: 550 Nl/min at 6/0 bar 350 Nl/min at 6/5 bar Nl = Standard litre
Valve cross-section: 5 mm
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013
Degree of protection: EN 60529:2000
AS-Interface: EN 62026-2:2013
Profile: S-7.F
IO code: 7
ID code: F
ID1 code: F
ID2 code: F
Data bits (function via AS-Interface): input output
Electromagnetic compatibility: D0: IN1 -
Electromagnetic compatibility: D1: IN2 -
Electromagnetic compatibility: D2: IN3 OUT3
Electromagnetic compatibility: D3: IN4 OUT4
Parameter bits (programmable via AS-i): function
Electromagnetic compatibility: P0: not used
Electromagnetic compatibility: P1: not used
Electromagnetic compatibility: P2: not used
Electromagnetic compatibility: P3: not used
Ambient temperature: 0 ... 55 °C (32 ... 131 °F)
Storage temperature: -20 ... 85 °C (-4 ... 185 °F)
Degree of protection: IP65 according to EN 60529
Connection: cable piercing methos or terminals flat cable or standard round cable inputs: M12 x 1 quick disconnect outputs: plug-in hose connector (8 mm)
Mass: approx. 200 g
Mounting: DIN rail or screw mounting

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m