Pepperl+Fuchs 088806

LA39/LK39/31/40a/116

Thru-beam sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Series 39 sensors are characterized by their high performance level, compact housing design, and variety of available versions. These include thru-beam sensors with a 20 m detection range, retroreflective sensors with polarization filter for a 5 m detection range, energetic diffuse mode sensors with an 800 mm and 2000 mm detection range, and a background suppression sensor with 500 mm detection range. Fitted in a robust plastic housing, this series is ideal for tough industrial applications. Thru-beam sensor, 20 m detection range, infrared light, light/dark on, AC/DC version, relay contact output, sensitivity adjuster, terminal compartment, Light/dark ON, switchable, Supplied with mounting accessory, Degree of protection IP67fa. The sensors are supplied with 10 V to 30 V DC, or 24 V to 240 V AC/DC. Various transistor and relay outputs are available as signal outputs. Standard features include pre-fault diagnostics and pre-fault output. The switching element function can be changed using the light/dark switch.

Parametry techniczne

Emitter: LA39/116
Receiver: LK39/31/40a/116
Effective detection range: 0 ... 20 m
Threshold detection range: 25 m
Adjustment range: 2 ... 25 m
Reference target: receiver
Light source: IRED
Light type: modulated infrared light
Ambient light limit: IEC / EN 60947-5-2 , 10000 Lux
MTTFd: 916 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Operation indicator: LED red (emitter)
Function indicator: LED yellow: switching state LED red: pre-fault indication
Control elements: Sensing range adjuster, light-on/dark-on changeover switch
Operating voltage: 12 ... 240 V DC / 24 ... 240 V AC (50 ... 60 Hz)
Ripple: 10 %
No-load supply current: ≤ 60 mA receiver and emitter
Protection class: II, rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140
Power consumption: ≤ 3 VA
Time delay before availability: ≤ 300 ms
Switching type: light/dark on
Signal output: 1 relay output
Switching voltage: max. 240 V AC ; 150 V DC
Switching current: max. 3 A
Switching power: DC: max. 90 W AC: max. 750 VA
Switching frequency: ≤ 25 Hz
Response time: ≤ 20 ms
Product standard: EN 60947-5-2
EAC conformity: TR CU 020/2011 TR CU 004/2011
CCC approval: Certified by China Compulsory Certification (CCC)
Approvals: CE
Ambient temperature: -25 ... 55 °C (-13 ... 131 °F)
Storage temperature: -40 ... 70 °C (-40 ... 158 °F)
Housing width: 25 mm
Housing height: 64 mm
Housing depth: 75 mm
Degree of protection: IP67
Connection: terminal compartment PG9, ≤ 2.5 mm2
Material: Housing: PBT
Material: Optical face: PMMA
Mass: Emitter: approx. 90 g receiver: approx. 110 g
Scope of delivery: Mounting aid

Parametry logistyczne

ECCN:
Kraj pochodzenia: VN
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m