Pepperl+Fuchs 099344

KLD2-PR-Ex1.IEC1

Fieldbus Power Repeater

Bajo pedido. Envíenos un correo electrónico para consultar el precio y la disponibilidad.
"ucnguBrctvdgcxgt0eqo"

Descripción

Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segmentpa

Parámetros técnicos

Connection: Power Rail or terminals 59+, 60-
Rated voltage: 20 ... 35 V DC
Ripple: ≤ 10 %
Rated current: 410 mA ... 170 mA
Field-side: Connection: terminals 3, 18+; 2, 17-
Field-side: Rated voltage: 12.8 ... 13.4 V DC
Field-side: Rated current: max. 100 mA
Field-side: Terminating impedance: 100 Ω , integrated
Host-side: Connection: Power Rail or terminals 40, 55+, 41, 56-
Host-side: Rated voltage: 9 ... 32 V DC (supplied switch S2 in pos. I) 0 V DC (not supplied switch S2 in pos. II)
Host-side: Terminating impedance: 100 Ω switchable off and on via rotary switch S1: 1 -> on; 0 -> off
Field-side/Host-side: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V
Host-side/Supply: functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Field-side/Supply: safe galvanic isolation acc. to EN 50020, voltage peak value 375 V
All circuits/FE: functional insulation acc. to DIN EN 50178, rated insulation voltage 253 Veff
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013
Galvanic isolation: EN 50178, EN 50020
Electromagnetic compatibility: NAMUR NE 21
Degree of protection: IEC/EN 60529
Fieldbus standard: IEC 61158-2, ISA S 50.02 part 2
Climatic conditions: DIN IEC 721
Classification: 3K3
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -20 ... 85 °C (-4 ... 185 °F)
Relative humidity: < 75 %
Pollution degree: max. 2, according to IEC 60664
Connection type: Terminals
Core cross-section: up to 2.5 mm2
Housing: 100 mm x 115 mm x 107 mm
Degree of protection: IP20
Mass: approx. 600 g
Mounting: DIN rail mounting
EU-type examination certificate: PTB 99 ATEX 2142
Electromagnetic compatibility: Marking: II (1) G [Ex ia] IIC Ga II (1) D [Ex ia] IIIC Da
Supply: Maximum safe voltage: 253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Field-side: Voltage Uo: 15 V
Field-side: Current Io: 207.2 mA
Field-side: Power Po: 1.93 W
Field-side: Maximum safe voltage Um: 60 V (Attention! The rated voltage can be lower.)
Certificate: PF 15 CERT 3527 X
Field-side: Marking: II 3G Ex ec IIC T4 Gc
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012
FM approval: CoC 3008872
Directive conformity: Control drawing: No. 116-0190
Directive conformity: Approved for: Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, Group IIC T4
Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Parámetros logísticos

ECCN:
País de origen: DE
EAN:
Peso: 0,00 kg
Longitud: 0,00 m
Anchura: 0,00 m
Altura: 0,00 m