2868693
STEP-UPS/12DC/12DC/4
| Width: | 108 mm |
| Height: | 90 mm |
| Depth: | 61 mm |
| Installation distance right/left: | 0 mm / 0 mm |
| Installation distance top/bottom: | 0 mm / 0 mm |
| Degree of protection: | IP20 |
| Ambient temperature (operation): | 0 °C ... 40 °C |
| Ambient temperature (storage/transport): | -20 °C ... 45 °C |
| Max. permissible relative humidity (operation): | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class: | 3K3 (in acc. with EN 60721) |
| Degree of pollution: | 2 |
| Input voltage: | 12 V DC |
| Nominal input voltage: | 12 V DC |
| Input voltage range: | 10 V DC ... 16.5 V DC |
| Current consumption (charging process): | < 0.8 A (Charging (ICharge = max, IOut = 0)) |
| Current consumption (maximum): | 6 A |
| Current consumption (idle): | < 30 mA |
| Fixed backup threshold: | < 10 V |
| Variable connect threshold: | 1 V / 1 s |
| Input fuse, integrated: | 7 A (slow-blow, internal) |
| Nominal output voltage: | 12 V DC |
| Nominal output current (IN): | 4 A (0 °C ... 40 °C) |
| Nominal output voltage: | 12 V DC |
| Output voltage range (depends on the input voltage): | 10 V DC ... 15 V DC (UOut = UIn (t-1)) |
| Nominal output current (IN): | 4 A (0 °C ... 40 °C) |
| Efficiency: | > 97.4 % (Mains operation, with charged energy storage) |
| IQ technology: | no |
| Net weight: | 0.46 kg |
| Memory medium: | Lithium polymer |
| Protection class: | III |
| MTBF (IEC 61709, SN 29500): | > 1997000 h (40 °C) |
| Mounting position: | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions: | alignable: horizontally 0 mm, vertically 50 mm |
| Connection method: | Screw connection |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 2.5 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 2.5 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 12 |
| Stripping length: | 6.5 mm |
| Screw thread: | M3 |
| Connection method: | Screw connection |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 2.5 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 2.5 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 12 |
| Stripping length: | 6.5 mm |
| Screw thread: | M3 |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 2.5 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 2.5 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 12 |
| Stripping length: | 6.5 mm |
| Screw thread: | M3 |
| Quality check of battery: | Yes, every time it is charged and cyclically once a month |
| Deep discharge protection: | < 15 V DC |
| EMC requirements for noise immunity: | EN 61000-6-1 |
| EMC requirements for noise emission: | EN 61000-6-3 |
| Standard - Electrical safety: | EN 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: | EN 50178/VDE 0160 (PELV) |
| UL approvals: | UL Listed UL 508 |
| Electromagnetic compatibility: | Conformance with EMC Directive 2014/30/EU |
| Electrostatic discharge: | EN 61000-4-2 |
| Contact discharge: | 6 kV (Test Level 3) |
| Discharge in air: | 8 kV (Test Level 3) |
| Electromagnetic HF field: | EN 61000-4-3 |
| Frequency range: | 80 MHz ... 1 GHz |
| Test field strength: | 10 V/m (Test Level 3) |
| Frequency range: | 1 GHz ... 2 GHz |
| Test field strength: | 10 V/m (Test Level 3) |
| Frequency range: | 2 GHz ... 3 GHz |
| Test field strength: | 10 V/m (Test Level 3) |
| Comments: | Criterion A |
| Fast transients (burst): | EN 61000-4-4 |
| Input: | 2 kV (Test Level 3 - asymmetrical) |
| Output: | 2 kV (Test Level 3 - asymmetrical) |
| Signal: | 2 kV (Test Level 4 - asymmetrical) |
| Comments: | Criterion A |
| Surge voltage load (surge): | EN 61000-4-5 |
| Input: | 1 kV (Test Level 2 - symmetrical) |
| Output: | 1 kV (Test Level 2 - symmetrical) |
| Signal: | 1 kV (Test Level 2 - asymmetrical) |
| Comments: | Criterion A |
| Conducted interference: | EN 61000-4-6 |
| I/O/S: | asymmetrical |
| Frequency range: | 0.15 MHz ... 80 MHz |
| Voltage: | 10 V (Test Level 3) |
| Comments: | Criterion A |
| Criterion A: | Normal operating behavior within the specified limits. |
| Criterion B: | Temporary impairment to operational behavior that is corrected by the device itself. |
| REACh SVHC: | Lead 7439-92-1 |
| China RoHS: | Environmentally Friendly Use Period = 25; |
| eCl@ss 10.0.1: | 27040705 |
| eCl@ss 4.0: | 27040600 |
| eCl@ss 4.1: | 27040600 |
| eCl@ss 5.0: | 27040600 |
| eCl@ss 5.1: | 27040600 |
| eCl@ss 6.0: | 27040600 |
| eCl@ss 7.0: | 27040603 |
| eCl@ss 8.0: | 27040603 |
| eCl@ss 9.0: | 27040705 |
| ETIM 4.0: | EC000382 |
| ETIM 5.0: | EC000382 |
| ETIM 6.0: | EC000382 |
| ETIM 7.0: | EC000382 |
| UNSPSC 6.01: | 30211510 |
| UNSPSC 7.0901: | 39121011 |
| UNSPSC 11: | 39121011 |
| UNSPSC 12.01: | 39121011 |
| UNSPSC 13.2: | 39121011 |
| UNSPSC 18.0: | 39121011 |
| UNSPSC 19.0: | 39121011 |
| UNSPSC 20.0: | 39121011 |
| UNSPSC 21.0: | 39121011 |
| ТН ВЭД: | |
| Страна происхождения: | DE |
| EAN: | |
| Вес: | 0,595 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |