Phoenix Contact 2868622

STEP-PS/ 1AC/24DC/0.75/FL

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

Технические характеристики

Width: 36 mm
Height: 90 mm
Depth: 43 mm
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 30 mm / 30 mm
Degree of protection: IP20
Ambient temperature (operation): -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport): -40 °C ... 85 °C
Max. permissible relative humidity (operation): ≤ 95 % (at 25 °C, non-condensing)
Climatic class: 3K3 (in acc. with EN 60721)
Degree of pollution: 2
Nominal input voltage range: 100 V AC ... 240 V AC
Input voltage range: 85 V AC ... 264 V AC
AC frequency range: 45 Hz ... 65 Hz
Frequency range DC: 0 Hz
Current consumption: 0.3 A (120 V AC)
Nominal power consumption: 36.9 VA
Inrush current: < 15 A (typical)
Mains buffering time: typ. 15 ms (120 V AC)
Input fuse: 1.25 A (slow-blow, internal)
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi): 0.58
Type of protection: Transient surge protection
Protective circuit/component: Varistor
Nominal output voltage: 24 V DC ±1 %
Nominal output current (IN): 0.75 A (-25 °C ... 55 °C)
Output current Imax: 1.4 A
Derating: 55 °C ... 70 °C (2.5%/K)
Connection in parallel: Yes, for redundancy and increased capacity
Connection in series: yes
Feedback voltage resistance: ≤ 35 V DC
Protection against overvoltage at the output (OVP): < 35 V DC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
Residual ripple: < 75 mVPP (20 MHz)
Output power: 18 W
Typical response time: < 0.5 s
Peak switching voltages nominal load: < 15 mVPP (20 MHz)
Maximum power dissipation in no-load condition: < 0.5 W
Power loss nominal load max.: < 3.6 W
Net weight: 0.11 kg
Operating voltage display: Green LED
Efficiency: > 84 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500): > 926000 h (40 °C)
Insulation voltage input/output: 4 kV AC (type test)
Degree of protection: IP20
Protection class: II (in closed control cabinet)
Housing material: Polycarbonate
Foot latch material: POM (Polyoxymethylen)
Mounting position: horizontal DIN rail NS 35, EN 60715
Assembly instructions: alignable: 0 mm horizontally, 30 mm vertically
Connection method: Screw connection
Conductor cross section solid min.: 0.2 mm²
Conductor cross section solid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
Connection method: Screw connection
Conductor cross section solid min.: 0.2 mm²
Conductor cross section solid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
EMC requirements for noise immunity: EN 61000-6-1
EMC requirements for noise emission: EN 61000-6-3
Budgetary standard: IEC 60335-1
Standard - Safety of transformers: EN 61558-2-16
Standard - Electrical safety: IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage: IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation: DIN VDE 0100-410
Standard – Limitation of mains harmonic currents: EN 61000-3-2
Standard - Approval for medical use: IEC 60601-1, 2 x MOOP
Rail applications: EN 50121-4
UL approvals: UL/C-UL listed UL 508
CSA: CSA-C22.2 No. 107.1-01
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge: EN 61000-4-2
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Electromagnetic HF field: EN 61000-4-3
Frequency range: 80 MHz ... 3 GHz
Test field strength: 10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst): EN 61000-4-4
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge): EN 61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
Output: 0.5 kV (Test Level 1 - symmetrical)
Comments: Criterion A
Conducted interference: EN 61000-4-6
Frequency range: 10 kHz ... 80 MHz
Voltage: 10 V (Test Level 3)
Comments: Criterion A
Voltage dips: EN 61000-4-11
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
REACh SVHC: Lead 7439-92-1
China RoHS: Environmentally Friendly Use Period = 25;
eCl@ss 10.0.1: 27040701
eCl@ss 4.0: 27040700
eCl@ss 4.1: 27040700
eCl@ss 5.0: 27242200
eCl@ss 5.1: 27242200
eCl@ss 6.0: 27049000
eCl@ss 7.0: 27049002
eCl@ss 8.0: 27049002
eCl@ss 9.0: 27040701
ETIM 2.0: EC001039
ETIM 3.0: EC001039
ETIM 4.0: EC002540
ETIM 5.0: EC002540
ETIM 6.0: EC002540
ETIM 7.0: EC002540
UNSPSC 6.01: 30211502
UNSPSC 7.0901: 39121004
UNSPSC 11: 39121004
UNSPSC 12.01: 39121004
UNSPSC 13.2: 39121004
UNSPSC 18.0: 39121004
UNSPSC 19.0: 39121004
UNSPSC 20.0: 39121004
UNSPSC 21.0: 39121004

Логистические характеристики

ТН ВЭД:
Страна происхождения: VN
EAN:
Вес: 0,11 kg
Длина: 0,00 m
Ширина: 0,00 m
Высота: 0,00 m