The VAA-2E2A-KE1-S/E2 is an AS-Interface safety module with 2 safety-related inputs and 2 conventional outputs. A dual channel mechanical switch or in each case a single channel mechanical switch can be connected to the two safety-related inputs. The outputs are conventional electronic outputs, which may be loaded in total with 1 A (max. 0,5 A per output). The housing, only 22.5 mm in width and 48.5 mm in height, takes up little place in the switch cabinet. The module features an integrated addressing jack is mounted by snapping onto the 35 mm DIN rail in accordance with EN 50022. Plug-in terminals are used for connection. A 4-way terminal block (black) is used for the inputs. The AS-Interface is connected via a double terminal block (yellow). The current switching state of each channel is indicated by an LED, located on the module's top side. Similarly, an LED is provided to monitor the AS-Interface communication and to indicate that the module has the address 0. If a communication error occurs, the outputs are de-energized (only P0=1). When single channel force-directed mechanical switches are connected, up to Performance level c in accordance with EN ISO 13849-1 can be achieved, given the appropriate wiring and selection of switch. When a two-channel force-directed mechanical switch is connected, up to Performance level e in accordance with EN ISO 13849-1 can be achieved, given the appropriate wiring and selection of switch. As per approval in accordance with IEC 61508 and IEC 62061 up to SIL 3 can be achieved. Both inputs of the module are assigned. The two channels of the mechanical switch are monitored for a cross circuit. LEDs are also provided to indicate AS-Interface voltage and external power supply.

Технические характеристики

Slave type: Safety-Slave
AS-Interface specification: V2.1
Required master specification: ≥ V2.1
UL File Number: E223772
Safety Integrity Level (SIL): SIL 3
Performance level (PL): PL e
MTTFd: 200 a
PFHd: 0
PFD: 0
LED FAULT: error display; LED red red: communication error or address is 0 red flashing: Output supply overload
LED PWR: AS-Interface voltage; LED green
LED AUX: ext. auxiliary voltage UAUX ; LED green
LED IN: switching state (input); 2 LED yellow
LED OUT: Switching state (output); 2 LED yellow
Auxiliary voltage (output): 20 ... 30 V DC PELV
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface
Rated operating current: ≤ 70 mA
Protection class: III
Surge protection: UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV)
Number/Type: 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input.
Supply: from AS-Interface
Voltage: 20 ... 30 V DC pulsed
Current loading capacity: input current limited ≤ 15 mA, overload and short-circuit resistant
Number/Type: 2 conventional electronic outputs, PNP
Supply: from external auxiliary voltage UAUX
Voltage: ≥ (UAUX - 0.5 V)
Current: 0.5 A per output
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 EN 61496-1:2004
Insulation coordination: EN 50178:1998
Electromagnetic compatibility: EN 61000-6-2:2005, EN 61000-4-5:2005 1 kV asymmetric, criterion B, EN 61000-6-4:2007
Degree of protection: EN 60529:2000
Fieldbus standard: EN 62026-2:2013
Electrical safety: EN 50178:1998 IEC 60204-1:2007
Emitted interference: EN 61000-6-4:2007
AS-Interface: EN 62026-2:2013
Functional safety: EN ISO 13849-1:2015 up to PL e, IEC 61508:2010 and IEC 62061:2005/A2:2015 up to SIL 3
Standards: NFPA 79:2002
Profile: S-7.B
IO code: 7
ID code: B
ID1 code: F
ID2 code: 0
Data bits (function via AS-Interface): input output
Electromagnetic compatibility: D0: dyn. safety code 1 OUT 1
Electromagnetic compatibility: D1: dyn. safety code 1 OUT 2
Electromagnetic compatibility: D2: dyn. safety code 2 -
Electromagnetic compatibility: D3: dyn. safety code 2 -
Parameter bits (programmable via AS-i): function
Electromagnetic compatibility: P0: Logic operation: P0 = 1 (default settings): The outputs are controlled via AS-Interface. P0 = 0: The outputs are controlled via AS-Interface or the inputs. The corresponding output is activated on opening the contacts of an input.
Electromagnetic compatibility: P1: not used
Electromagnetic compatibility: P2: not used
Electromagnetic compatibility: P3: not used
Ambient temperature: -25 ... 50 °C (-13 ... 122 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 85 % , noncondensing
Climatic conditions: For indoor use only
Altitude: ≤ 2000 m above MSL
Shock and impact resistance: 10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance: 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree: 2
Degree of protection: IP20
Connection: removable spring terminals Conductor cross-section 0,25 ... 2,5 mm2
Material: Housing: PA 66-FR
Mass: 80 g
Mounting: DIN mounting rail
Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm