301161
NBB3-V3-Z4-3G-3D
Inductive sensor
Series: Rectangular type, Housing material: PBT, Output type: 2-wire, Installation: flush, Type of voltage: DC, Connection type: cable PVC , 130 mm, Degree of protection: IP67fa
| Switching function: | Normally open (NO) |
| Output type: | Two-wire |
| Rated operating distance: | 3 mm |
| Installation: | flush |
| Output polarity: | DC |
| Assured operating distance: | 0 ... 2.4 mm |
| Actual operating distance: | 2.7 ... 3.3 mm typ. |
| Reduction factor rAl: | 0.45 |
| Reduction factor rCu: | 0.35 |
| Reduction factor r304: | 0.8 |
| Reduction factor rBrass: | 0.5 |
| Output type: | 2-wire |
| Operating voltage: | 5 ... 60 V DC |
| Switching frequency: | 0 ... 2000 Hz |
| Hysteresis: | typ. 0.2 mm |
| Reverse polarity protection: | reverse polarity protected |
| Short-circuit protection: | no |
| Inductive overvoltage protection: | yes |
| Voltage drop: | ≤ 4 V |
| Voltage drop at IL: Voltage drop IL = 10 mA, switching element on: | 3.4 ... 3.9 V typ. 3.6 V |
| Operating current: | 4 ... 100 mA |
| Lowest operating current: | 4 mA |
| Off-state current: | 0.4 ... 0.55 mA typ. 0.46 mA |
| Time delay before availability: | ≤ 1 ms |
| Switching state indicator: | LED, yellow |
| Tightening torque, fastening screws: | 0.4 Nm |
| MTTFd: | 1552 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| EMC in accordance with: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| UL approval: | cULus Listed, General Purpose |
| CSA approval: | cCSAus Listed, General Purpose |
| Ambient temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Connection type: | cable PVC , 130 mm |
| Core cross-section: | 0.14 mm2 |
| Housing material: | PBT |
| Sensing face: | PBT |
| Degree of protection: | IP67 |
| Cable: Bending radius: | > 10 x cable diameter |
| Certificate: | PF 15CERT3754 X |
| CE marking: | [*PD-Z02586A*] |
| ATEX marking: | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. |
| Standards: | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category "n" Use is restricted to the following stated conditions |
| Special conditions: Maximum operating current IL: | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. |
| Special conditions: Maximum operating voltage UBmax: | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. |
| Special conditions: Maximum permissible ambient temperature TUmax: | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
| Special conditions: at UBmax=60 V, IL=100 mA: | 38 °C (100.4 °F) |
| Special conditions: at UBmax=60 V, IL=50 mA: | 52 °C (125.6 °F) |
| Special conditions: at UBmax=60 V, IL=25 mA: | 57 °C (134.6 °F) |
| Special conditions: at UBmax=30 V, IL=100 mA: | 36 °C (96.8 °F) |
| Special conditions: at UBmax=30 V, IL=50 mA: | 50 °C (122 °F) |
| Special conditions: at UBmax=30 V, IL=25 mA: | 57 °C (134.6 °F) |
| CE marking: | [*PD-Z02586A*] |
| ATEX marking: | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. |
| Standards: | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. |
| General: | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. |
| Special conditions: Maximum permissible ambient temperature TUmax: | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. |
| Special conditions: at UBmax=60 V, IL=100 mA: | 38 °C (100.4 °F) |
| Special conditions: at UBmax=60 V, IL=50 mA: | 52 °C (125.6 °F) |
| Special conditions: at UBmax=60 V, IL=25 mA: | 57 °C (134.6 °F) |
| Special conditions: at UBmax=30 V, IL=100 mA: | 36 °C (96.8 °F) |
| Special conditions: at UBmax=30 V, IL=50 mA: | 50 °C (122 °F) |
| Special conditions: at UBmax=30 V, IL=25 mA: | 57 °C (134.6 °F) |
| Use in the hazardous area: | see instruction manuals |
| Special conditions: Category: | 3G; 3D |
| ТН ВЭД: | |
| Страна происхождения: | ID |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |