Pepperl+Fuchs 254800

LB5005A

Thermocouple Converter

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

The thermocouple converter accepts thermocouple or mV signals from the field. 4 channels, Converter for thermocouples and mV-signals, Installation in Zone 2 or safe area, Simulation mode for service operations (forcing)pa. Open circuit line fault alarms are detected. The inputs are galvanically isolated from the bus and the power supply (EN 60079-11). There is a functional isolation between the channels.

Технические характеристики

Occupied slots: 2
Connection: backplane bus
Rated voltage: 12 V DC , only in connection with the power supplies LB9***
Power dissipation: 0.75 W
Power consumption: 0.75 W
Connection: backplane bus
Interface: manufacturer-specific bus to standard com unit
Compensation (reference junction CJC): internal cold junction compensation or external cold junction
Number of channels: 4
Suitable field devices: Field device [2]: Thermocouple
Suitable field devices: Field device [4]: mV source
Suitable sensors: Sensor: thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connection: channel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Measurement range: -65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Smallest span: 5 mV for 0.1 % accuracy
Linearity error: 0.1 %
Conversion time: max. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Compensation (reference junction CJC): internal cold junction compensation or external cold junction
Test voltage: 1.5 kV input - input 1.5 kV input - bus and auxiliary power
Line fault detection: can be switched on/off for each channel via configuration tool ,
Suitable sensors: Open-circuit: > 1 kΩ
Deviation: Influence of ambient temperature: max. 0,1 %/10 K
LED indication: Power LED (P) green: supply Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding: optional mechanical coding via front socket
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1
Electromagnetic compatibility: NE 21
Degree of protection: IEC 60529
Environmental test: EN 60068-2-14
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Damaging gas: EN 60068-2-42
Relative humidity: EN 60068-2-56
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 95 % non-condensing
Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Degree of protection: IP20 when mounted on backplane
Connection: removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Mass: approx. 150 g
Dimensions: 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Certificate: PF 08 CERT 1234 X
Electromagnetic compatibility: Marking: II 3 G Ex nA [ic] IIC T4 Gc
Galvanic isolation: Input/input: functional insulation acc. to IEC 60664-1:2007, rated insulation voltage 50 V, testing voltage 500 V
Galvanic isolation: Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010
IECEx approval: BVS 09.0037X
Directive conformity: Approved for: Ex nA [ic] IIC T4 Gc
Marine approval: Lloyd Register: 15/20021
Marine approval: DNV GL Marine: TAA0000034
Marine approval: Bureau Veritas Marine: 22449/B0 BV
System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.