251408
VBA-4E4E-G11-ZAJ-F
AS-Interface sensor module
G11 module. 2 x 4 inputsfa. The VBA-4E4E-G12-ZAJ is an AS-Interface switch-on module with 8 inputs. The switch-on module is equipped with 2 separate AS-Interface chips and uses 2 A/B addresses. In the delivered state, both slave addresses use the address 0. The second slave is deactivated until the first slave is addressed. Duplicate addressing is avoided in this way. 2 and 3-wire sensors can also be connected as mechanical contacts to the PNP electronic inputs. The housing with a central screw enables fast mounting on the base plate. The connection to the sensors is via an M12x1 plug-in connection on the top side of the device. The AS-Interface flat cable is connected via the insulation piercing technology on the underside of the module. The inputs and the connected sensors are powered by the internal supply of the module (from the AS-Interface). The current switching state of each input is indicated via an IN LED. The AS-i/FAULT LEDs indicate the status of the AS-Interface (normal operation, communication error, peripheral fault, address 0). The switch-on module has a double addressing jack and is compatible with AS-Interface POWER24.
| Slave type: | A/B slave |
| AS-Interface specification: | V3.0 |
| Required master specification: | ≥ V2.1 |
| UL File Number: | E223772 |
| MTTFd: | 120 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| LED AS-i/FAULT: | 2 Dual LEDs green/red green: AS-Interface voltage red: Communication error yellow/red flashing: Address 0 green/red flashing: Sensor supply overload |
| LED IN: | switching state (input); 8 LED yellow |
| Rated operating voltage: | 18,0 ... 31.6 V from AS-Interface |
| Rated operating current: | ≤ 80 mA (without sensors) / max. 280 mA |
| Protection class: | III |
| Surge protection: | Ue: Over voltage category III, safe isolated power supplies (PELV) |
| Number/Type: | 2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC |
| Supply: | from AS-Interface |
| Voltage: | 12 ... 31 V |
| Current loading capacity: | ≤ 200 mA, overload and short-circuit protected |
| Input current: | ≤ 9 mA (limited internally) |
| Switching point: | according to DIN EN 61131-2 (Type 2) |
| : 0 (unattenuated): | ≤ 3 mA |
| : 1 (attenuated): | ≥ 5 mA |
| Signal delay: | < 1 ms (input/AS-Interface) |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Degree of protection: | EN 60529:2000 |
| Fieldbus standard: | EN 62026-2:2013 |
| Input: | EN 61131-2:2007 |
| Emitted interference: | EN 61000-6-4:2007 |
| AS-Interface: | EN 62026-2:2013 |
| Noise immunity: | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
| Profile: | S-0.A.2 |
| IO code: | 0 |
| ID code: | A |
| ID1 code: | Slave 1 Slave 2 1 2 |
| ID2 code: | 2 |
| Data bits (function via AS-Interface): | Input slave 1 input slave 2 |
| Electromagnetic compatibility: D0: | IN1.1 IN2.1 |
| Electromagnetic compatibility: D1: | IN1.2 IN2.2 |
| Electromagnetic compatibility: D2: | IN1.3 IN2.3 |
| Electromagnetic compatibility: D3: | IN1.4 IN2.4 |
| Parameter bits (programmable via AS-i): | function |
| Electromagnetic compatibility: P0: | not used |
| Electromagnetic compatibility: P1: | Input filter P1 = 0 input filter on, pulse suppression ≤ 2 ms P1 = 1 input filter off (default settings) |
| Electromagnetic compatibility: P2: | Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings) |
| Electromagnetic compatibility: P3: | not used |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity: | 85 % , noncondensing |
| Climatic conditions: | For indoor use only |
| Altitude: | ≤ 2000 m above MSL |
| Shock and impact resistance: | 30 g, 6 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
| Vibration resistance: | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles |
| Pollution degree: | 3 |
| Degree of protection: | IP68 / IP69K |
| Connection: | AS-Interface: AS-Interface flat cable Inputs: M12 round connector |
| Material: Housing: | PBT PC |
| Material: Mounting screw: | Stainless steel 1.4305 / AISI 303 |
| Mass: | 200 g |
| Tightening torque, housing screws: | 1.8 Nm |
| Tightening torque, cable gland: | 0.4 Nm |
| Mounting: | Mounting plate |
| ТН ВЭД: | |
| Страна происхождения: | SG |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |