235088
NBN3-F31K2M-E8-B13-S-3G-3D
Inductive sensor
Series: Double sensor, Housing material: rugged polycarbonate (PC) + GF 10% , optimised for outdoor use, Output type: 4-wire, Installation: for non-flush mounting, Type of voltage: DC, Connection type: screw terminals, Degree of protection: IP67 ; additional degree of protection IP66/IP69 with BT65-F31K2-RG-EN-01 and SH-F31K2-B13fa
| Switching function: | 2 x normally open (NO) |
| Output type: | PNP |
| Rated operating distance: | 2.5 mm |
| Installation: | for non-flush mounting |
| Output polarity: | DC |
| Assured operating distance: | 0 ... 1.5 mm |
| Output type: | 4-wire |
| Operating voltage: | 10 ... 30 V |
| Switching frequency: | 0 ... 100 Hz |
| Hysteresis: | typ. 5 % |
| Reverse polarity protection: | all connections |
| Short-circuit protection: | pulsing |
| Voltage drop: | ≤ 3 V |
| Operating current: | 0 ... 100 mA |
| Off-state current: | 0 ... 0.5 mA typ. 0.1 µA |
| No-load supply current: | ≤ 25 mA |
| MTTFd: | 490 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Voltage: | max. 32 V DC |
| Current: | max. 240 mA |
| Short-circuit protection: | no |
| Reverse polarity protection: | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
| Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 VDI / VDE 3845 |
| Ambient temperature: | -40 ... 75 °C (-40 ... 167 °F) , restriction for use in hazardous area, see instruction manual |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Connection type: | screw terminals |
| Connection (system side): | screw terminals , M20 x 1.5 cable gland , usable thread length 13.5 mm , screw-in depth max. 13.5 mm ground connection with earthing screw only for wire cross-section 4 mm2, use solid wire or stranded wire with wire end ferrule |
| Connection (valve side): | screw terminal , Cable gland M20 x 1.5 |
| Housing material: | rugged polycarbonate (PC) + GF 10% , optimised for outdoor use |
| Housing base: | powder coated aluminum |
| Degree of protection: | IP67 ; additional degree of protection IP66/IP69 with BT65-F31K2-RG-EN-01 and SH-F31K2-B13 |
| Terminal assembly: Number: | 10 |
| Terminal assembly: Connection type: | For connection of copper wires with 7 mm dismantle length Tightening torque 0.5 ... 0.6 Nm |
| Terminal assembly: Type: | Screw terminal block, pluggable |
| Terminal assembly: Terminal capacity: | Conductor cross-section 0,25 ... 2,5 mm2 , flexible/rigid For Multiple-wire connection: two wires of equal cross-section per 0.25 ... 1 mm2 |
| Tightening torque, fastening screws: | 2 Nm |
| Tightening torque, housing screws: | 1.5 Nm |
| Tightening torque, earthing screw: | 1.5 Nm |
| Tightening torque, cable gland: | M20 x 1.5 ; max. 11 Nm |
| Tightening torque, stopping plug: | 2 Nm |
| Use in the hazardous area: | see instruction manuals |
| ТН ВЭД: | |
| Страна происхождения: | CZ |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |