Pepperl+Fuchs 225875

VAN-115/230AC-K19

AS-Interface power supply

По запросу. Пожалуйста, отправьте нам письмо, чтобы узнать цену и наличие.
"ucnguBrctvdgcxgt0eqo"

Описание

The primary pulsed power supply was developed for fieldbus applications that transfer power and data via one two-wire line. AS-Interface concept). With an output current of 2.8 A, it supplies a fully configured AS-Interface system. AS-Interface power supply, data decoupling, 2,8 Afa. In this case, the power supply is responsible for supplying power, decoupling the data to the supply source and providing for symmetry of the two output lines (AS-Interface + and AS-Interface -) relative to the machine mass (shield connection). The exact and transformatory coupling permits the use of unshielded load lines. The input voltage range of the device can be selected with a switch. Thus, the power supply can be operated on all conventional single-phase mains voltages worlwide. Fusing:. The power supply is protected electronically against external short circuits. The internal fuse disconnects the power supply from the network in the case of a defect.

Технические характеристики

UL File Number: E223176
MTBF: 221 a
LED AS-i ok: LED green: ON: AS-Interface voltage OK OFF: overload or no supply voltage
Fusing: 2.5 AT (not replacable)
Capacity factor: > 0.5
Rated operating voltage: nominal: 100 ... 120 VAC/220 ... 240 VAC permissible: 85 ... 132 VAC/184 ... 264 VAC
Rated operating current: 2.0 A at 115 VAC 0.9 A at 230 VAC
Supply frequency: 47 ... 63 Hz
Efficiency: 90.5 % (230 VAC, 2.8 A)
Current limit: > 3.2 A
Voltage: 30.55 VDC ± 3 % fixed
Current: 2.8 A
Residual ripple: ≤ 50 mVss (500 kHz bandwidth, 50-Ω-measurement with ohmic load)
Short-circuit current: min. 3.2 A, max. 4.6 A
Directive conformity: Low Voltage Directive 2006/95/EC: EN 60950-1:2006, EN 61204-3:2001
Directive conformity: EMC Directive 2004/108/EC: EN 61000-6-2:2005, EN 61000-6-3:2007, EN 50295:1999
Standard conformity: Electromagnetic compatibility: EN 61000-6-2:2005; EN 61000-6-3:2007
Standard conformity: AS-Interface: EN 50295:1999, IEC 62026-2:2006
Standard conformity: Mech. capacity: EN 60068-2-6:2008
Standard conformity: Shock and impact resistance: EN 60068-2-27:1995
Ambient temperature: -10 ... 70 °C (14 ... 158 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Shock and impact resistance: 15g/6 ms 10g/11 ms
Vibration resistance: 2 ... 17,8 Hz / 1.6 mm 17.8 ... 500 Hz / 2.0 g
Pollution degree: 2 (EN 60950)
Degree of protection: IP20
Protection class: I, Protective conductor connection necessary
Connection: Connection terminals, max. conductor cross-section 0.5 ... 6 mm2 (20-10 AWG), Stripping length 7 mm
Mass: approx. 500 g
Mounting: DIN mounting rail

Логистические характеристики

ТН ВЭД:
Страна происхождения: DE
EAN:
Вес: 0,00 kg
Длина: 0,00 m
Ширина: 0,00 m
Высота: 0,00 m