Robust diffuse mode sensor for monitoring web breaks, compact housing design, foreground and background suppression, 60 mm detection range, infrared light, push-pull output, weak signal output, M12 plug, Special device for paper web break control and printing machinery, Active contamination detection, Sensing range 20 mm ... 60 mm, Light scanner with foreground suppression 0 mm ... 15 mm and background suppression beyond 70 mmfa
| Foreground suppression: | 0 ... 15 mm |
| Detection range: | on black (6 %): 20 ... 60 mm fixed |
| Detection range min.: | 20 ... 60 mm |
| Detection range max.: | 16 ... 70 mm |
| Background suppression: | starts from 70 mm |
| Light source: | IRED |
| Light type: | modulated infrared light , 880 nm |
| Polarization filter: | no |
| Black/White difference (6 %/90 %): | < 1 % at 60 mm |
| Diameter of the light spot: | max. 6 mm at a distance of 70 mm |
| Angle of divergence: | approx. 4 ° |
| Ambient light limit: | 50000 Lux |
| MTTFd: | 1260 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Operation indicator: | LED green, statically lit Power on, short-circuit or low voltage : pulsing (1 Hz). Pollution : flashing (1 Hz) |
| Function indicator: | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range |
| Operating voltage: | 10 ... 30 V DC |
| Ripple: | 10 % |
| No-load supply current: | max. 25 mA |
| Test input: | emitter deactivation at +UB |
| Pre-fault indication output: | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected |
| Signal output: | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected |
| Switching voltage: | max. 30 V DC |
| Switching current: | max. 100 mA |
| Voltage drop: | ≤ 2.5 V DC |
| Switching frequency: | 250 Hz |
| Response time: | 2 ms |
| Product standard: | EN 60947-5-2 |
| Protection class: | II, rated voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 |
| UL approval: | cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure) |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | 0 ... 70 °C (32 ... 158 °F) |
| Storage temperature: | -40 ... 75 °C (-40 ... 167 °F) |
| Housing width: | 31 mm |
| Housing height: | 56.5 mm |
| Housing depth: | 13.6 mm |
| Degree of protection: | IP67 |
| Connection: | 5-pin, M12 x 1 connector |
| Material: Housing: | Aluminum , Delta-Seal coated |
| Material: Optical face: | glass pane |
| Material: Connector: | metal |
| Mass: | 50 g |
| ТН ВЭД: | |
| Страна происхождения: | SG |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |