204401
RLK28-55-Z-2466/31/115d
Retroreflective sensor
Retroreflective sensor with polarization filter, Ultra bright LEDs for power on, weak signal indication and switching state, Programmable time function GAN, GAB, IAB, as well as GAN-GAB and GAN-IAB as double function, Not sensitive to ambient light, even with switched energy saving lamps, Protection class IIfa
| Effective detection range: | 0 ... 17 m |
| Reflector distance: | 0.05 ... 17 m |
| Threshold detection range: | 21 m |
| Reference target: | H85-2 reflector |
| Light source: | LED |
| Light type: | modulated visible red light , 660 nm |
| Polarization filter: | yes |
| Diameter of the light spot: | approx. 290 mm at a distance of 17 m |
| Angle of divergence: | emitter 1.2° receiver 2° |
| Ambient light limit: | 80000 Lux |
| MTTFd: | 600 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Operation indicator: | LED green |
| Function indicator: | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted |
| Control elements: | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch |
| Operating voltage: | 12 ... 240 V AC/DC |
| Power consumption: | ≤ 3.5 VA |
| Switching type: | light/dark on, switchable (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.) |
| Signal output: | Relay, 1 alternator |
| Switching voltage: | max. 250 V AC/DC |
| Switching current: | max. 2 A |
| Switching power: | DC: max. 50 W AC: max. 500 VA |
| Switching frequency: | 25 Hz |
| Response time: | 20 ms |
| Timer function: | ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment interval 0.1 ... 10 s |
| Product standard: | EN 60947-5-2 |
| Protection class: | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
| Ambient temperature: | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature: | -40 ... 75 °C (-40 ... 167 °F) |
| Housing width: | 25.8 mm |
| Housing height: | 88 mm |
| Housing depth: | 65.5 mm |
| Degree of protection: | IP65 |
| Connection: | 7-pin surface-mounted connector, up to 250 VAC (without cable socket) |
| Material: Housing: | Plastic ABS |
| Material: Optical face: | Plastic pane |
| Mass: | 180 g |
| ТН ВЭД: | |
| Страна происхождения: | VN |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |