199290-0035
WCS3B-LS311S
Read head
Reading head, SSI interface, Gray code, SSI interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Speed transferfa
| Passage speed: | ≤ 12.5 m/s |
| Measuring range: | max. 314.5 m |
| Free tolerances to code rail: | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |
| Resolution: | ± 0.4 mm (1,250 positions/m) |
| MTTFd: | 170 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Operation indicator: | LED green: power on |
| Velocity indicator: | LED yellow off, if speed limit is exceeded |
| Error indicator: | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
| Operating voltage: | 10 ... 30 V DC |
| Power consumption: | 2 VA |
| Interface type: | SSI interface |
| Data output code: | Gray code , 25 bit |
| Clock frequency: | 100 ... 1000 kHz |
| Pause time: | ≥ 20 µs double request possible, if tp ≤ 10 µs |
| Output velocity: | switch output , short-circuit protected |
| Switching voltage: | Operating voltage |
| Emitted interference: | DIN EN 61000-6-4 |
| Noise immunity: | DIN EN 61000-6-2 |
| Shock resistance: | DIN EN 60068-2-27, half sine 30 g, 18 ms |
| Vibration resistance: | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
| CSA approval: | cCSAus Certified, General Purpose Class 2 power source |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Operating temperature: | 0 ... 60 °C (32 ... 140 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | 90 % , noncondensing |
| Connection type: | 8-pin, M12 x 1 connector |
| Degree of protection: | IP54 |
| Material: Housing: | ABS , PC (Polycarbonate) |
| Mass: | 500 g |
| Ordering information: | Mounting plate included with delivery |
| ТН ВЭД: | |
| Страна происхождения: | DE |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |