Background suppression sensor, Universal series with highly versatile fields of use, Resistant against noise: reliable operation under all conditions, Good alignability due to red transmission LED, Programmable time function GAN, GAB, IAB and GAN-IAB as double function, Version for universal voltagesfa
| Detection range: | 20 ... 700 mm |
| Detection range min.: | 20 ... 200 mm |
| Detection range max.: | 20 ... 700 mm |
| Adjustment range: | 200 ... 700 mm |
| Background suppression: | max. + 10 % of the upper limit of the detection range |
| Light source: | LED |
| Light type: | modulated visible red light , 660 nm |
| Black/White difference (6 %/90 %): | < 20 % |
| Diameter of the light spot: | approx. 15 mm at a distance of 700 mm |
| Angle of divergence: | Emitter 1.2°, Receiver 2° |
| Ambient light limit: | 50000 Lux |
| MTTFd: | 620 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Operation indicator: | LED green |
| Function indicator: | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range |
| Control elements: | Sensing range adjuster , Light-on/dark-on changeover switch |
| Operating voltage: | 12 ... 240 V AC/DC |
| Power consumption: | ≤ 3.5 VA |
| Switching type: | light/dark on, switchable (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.) |
| Signal output: | Relay, 1 alternator |
| Switching voltage: | max. 250 V AC/DC |
| Switching current: | max. 2 A |
| Switching power: | DC: max. 50 W AC: max. 500 VA |
| Switching frequency: | 25 Hz |
| Response time: | 20 ms |
| Timer function: | ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment interval 0.1 ... 10 s |
| Product standard: | EN 60947-5-2 |
| EAC conformity: | TR CU 020/2011 TR CU 004/2011 |
| Protection class: | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
| UL approval: | E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
| CCC approval: | Certified by China Compulsory Certification (CCC) |
| Ambient temperature: | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature: | -40 ... 75 °C (-40 ... 167 °F) |
| Housing width: | 25.8 mm |
| Housing height: | 88 mm |
| Housing depth: | 65.5 mm |
| Degree of protection: | IP67 |
| Connection: | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2, insulation stripping 7.5 ... 8.5 mm, M16 x 1.5 cable gland |
| Material: Housing: | Plastic ABS |
| Material: Optical face: | Plastic pane |
| Mass: | 112 g |
| ТН ВЭД: | |
| Страна происхождения: | VN |
| EAN: | |
| Вес: | 0,00 kg |
| Длина: | 0,00 m |
| Ширина: | 0,00 m |
| Высота: | 0,00 m |